Safety Instructions; Purpose; Symbols Used; Unit Management - Carel HumiSonic Manual Del Usuario

Humidificadores por ultrasonidos
Ocultar thumbs Ver también para HumiSonic:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENG
Safety instructions are required by law. These are intended to ensure
safety in the workplace and prevent accidents.

2.1 Purpose

To comply with the national and local regulations in force for the
prevention of personal and third-party injuries.

2.2 Symbols used

The symbols used to represent hazards correspond to the warning
messages specified in accordance with EN 82079-1 (and ANSI Z535.6):
DANGER: Indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided,
may result in light or moderate injury.
NOTICE: Indicates a potentially hazardous situation which may cause
damage to surrounding property and equipment.

2.3 Unit management

Do not carry out any work that compromises the safety of the humidifier.
Follow all safety instructions and warnings marked on the unit.
In the event of a malfunction or power failure, immediately switch the
unit off and prevent it from being switched on again. Repair any faults
promptly.
WARNING
Reserved use.
IEC 60335-1 states the following: this appliance can be used by children
aged from 8 years and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Cleaning and user
maintenance shall not be made by children unless they are supervised.

2.4 Operation of the unit

WARNING
Burn hazard!
The humidifier contains high-temperature components. For electrode,
heater or gas-fired isothermal humidifiers, in the event of leaks or
component faults, uncontrolled release of steam at 100°C/212°F may be
possible. Switch the unit off immediately.
Steam production is only allowed when the unit's cover is closed.
NOTICE: Risk of damage to the appliance!
The appliance may be damaged if switched on repeatedly following an
unrepaired fault. Repair any malfunctions promptly.
The appliance must not be operated with a DC power supply.
Regularly check that all safety and monitoring devices are working
properly. Do not remove or disable the safety devices.
NOTICE:
Possibility of water leaks due to faulty connections or
malfunctions.
Water is continuously and automatically fed into and drained by the
humidifier. The connections and components that carry water must be
regularly checked to ensure they are working perfectly.
Direct version for room applic. +0300062EE - rel. 1.4 - 24.09.2020

2. SAFETY INSTRUCTIONS

6
2.5 Assembly, disassembly, maintenance
and repair of the unit
NOTICE
The humidifier's protection rating is IP20. Make sure that it is not affected
by dripping water in the site of installation.
Installation of the humidifier in a place without a water drainage system
requires the presence of safety devices that, in the event of water leaks,
can safely shut off the water supply to the humidifier.
• Only use original spare parts.
• After any repairs, make sure that safe operation of the unit is checked
by qualified personnel.
• Connection or installation of additional components is only allowed
with the written authorisation of the manufacturer.
WARNING
Do not install the humidifier on top of electrical devices such as fuse
boxes, household appliances, etc. In the event of water leaks, this may
damage the electrical equipment below.

2.6 Electrical system

WARNING
Electric shock hazard!
Dangerous electrical voltage.
Work on the electrical system must only be carried out by qualified
personnel (electrician or technician with equivalent training). During
maintenance or installation work, the appliance must be disconnected
from the mains power supply and must be prevented from being
powered on. Electrical disconnection must be verified by measurement.
The humidifier can only be started when the cover is closed.
Water leaks may cause leakage current. Observe the safety rules when
working on parts that may be live.
After electrical installation or repair work, check all safety devices (e.g.
earth resistor).
NOTICE
Only use original fuses with the correct amperage. Regularly check the
electrical parts of the equipment. Promptly repair any damage, such as
loose connections, burnt wiring or defective electrical insulation.
Responsibility for intrinsically safe installation of the humidifier lies with
the company that carried out installation.

2.7 Disposal after decommissioning

NOTICE The system manager is responsible for disposal of the appliance's
components as specified by law. See 1.2