INSTRUCTION MANUAL (Translation from the original Spanish)
Damage prevention and safety instructions
A Warning! Observe limitations of use.
B The name plate voltage must be the same as the
mains voltage.
C Connect the unit to the mains via an omnipolar
switch with at least a 3mm opening between con-
tacts.
D Install a high- sensitivity differential switch (0.03A)
as extra protection against lethal electric shocks.
E Connect the unit to the ground.
F Use unit only within performance limits indicated
on the name plate.
Remembertoprimepump.
G
Check for motor self-ventilation.
H
Contents
Safety precautions ....................................................... 5
1. General information ................................................ 5
2. Handling ................................................................. 6
3. Installation ............................................................. 6
3.1. Fixing ................................................................. 6
4.
Starting ................................................................... 6
5. Maintenance ........................................................... 7
9. Wiring diagrams .................................................... 26
10. Illustrations............................................................ 26
Safety precautions
This symbol
following words "Danger" or "Warning" indicates the
risk level deriving from failure to observe the pre-
scribed safety precautions:
Warns that failure to observe
DANGER
the pre cautions involves a risk
risk of
of electric shock.
electric
shock
Warns that failure to observe
DANGER
the pre cautions involves a risk
of damage to persons and/or
things.
Warns that failure to observe
WARNING
the pre cautions involves the
risk of damaging the pump
and/or the facility
together with one of the
(See figure8)
This apparatus may be used by children 8 years
I
or older and persons with reduced physical, sen-
sory or mental capacities, or lacking experience
and knowledge, if they are supervised or receive
adequate training on the safe use of the appara-
tus and understand the dangers.
Children should not be allowed to play with the
apparatus.
Children should not perform the ordinary clean-
ing and maintenance tasks without supervision.
J Be careful with hazardous liquids and environ-
ments.
Caution! Look out for accidental leaks.
K
Do not expose pump to bad weather.
Caution! Avoid icing.
L
Cut out power supply before servicing pump.
According to IEC 60730-2-6, this is a unit of inde-
pendent assembly, type 1B, for flood proof
installation in clean or slightly contaminated envi-
ronments. Pollution degree 2.
Pulse rating voltage 2500 V.
1. GENERAL INFORMATION
These instructions are designed to ensure the correct
installation and best use of our automatic constant
water pressure assemblies.
Read these instructions before installing the
unit.
Save them for future reference.
Correct pump operation is assured providing
the instructions on electrical connection, instal-
lation and use are strictly adhered to.
Failure to adhere to the instructions can result
in premature failure of the pump and voiding of
the warranty.
PRESSDRIVE is completely silent and are designed
to provide an automatic supply of clean water to one
or two dwellings.
It is a compact kit comprising a check valve, electronic
circuit and reset button.
It is designed to maintain constant pressure. It does
not permit the pump to operate without water and
avoids water hammering. It requires no preloading of
air or adjustment. It has a water reserve to prevent the
unit from being started by a dripping tap.
If water consumption is more than 1 l/min the pump
will operate continuously.
When the pump reaches maximum pressure the unit
automatically switches the pump off. Unit selection
must take into account the fact that the differential
must be over 0.7 bars.
5
EN