Care, Maintenance And Disposal; General; Recognising Faulty Wearing Parts - Fronius MTG 2500 S Manual De Instrucciones

Antorcha manual mig/mag
Ocultar thumbs Ver también para MTG 2500 S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43

Care, maintenance and disposal

General

Regular preventive maintenance of the welding torch is essential for problem-free opera-
tion. The welding torch is subjected to high temperatures and heavy soiling. The welding
torch therefore requires more frequent maintenance than other components in the welding
system.
Recognising
1.
faulty wearing
parts
1.
2.
3.
4.
5.
34
2.
Insulating parts
Burned-off outside edges, notches
Nozzle fittings
Burned-off outside edges, notches
Heavily covered in welding spatter
Spatter guard
Burned-off outside edges, notches
Contact tips
Worn-out (oval) wire entry and wire exit holes
Heavily covered in welding spatter
Fusion penetration on the tip of the contact tube
Gas nozzles
Heavily covered in welding spatter
Burned-off outside edges
Notches
NOTE! When removing welding
spatter, avoid scoring or scratch-
ing the torch. Future welding spat-
ter may become firmly lodged in
score or scratch marks.
Do not bend the torch neck under any cir-
cumstances!
3.
4.
5.

Publicidad