CONNECTIONS TO THE TERMINAL BLOCK AND STANDARD OPERATION R70 2AC
1-2-3 F-N-Terra Board power supply INPUT 230 Vac 50 Hz
4-5 COR-CLU Courtesy light OUTPUT (230 Vac 100 Wmax). Fixed voltage 230 Vac for motor operating time
6-5 LAM-CLU Flashing light OUTPUT (230 Vac 100 Wmax). Fixed voltage 230 Vac for motor operating time
7-8-9 AP1-CM-CH1 Motor 1 OUTPUT : M1 (single-phase 230Vac 40Wmax) motor with opening delay 2 seconds
10-11-12 AP2-CM-CH2 Motor 2 OUTPUT : M2 (single-phase 230Vac 40Wmax) motor with closing delay set by the trimmer: delay 2 seconds
13-14 ES-COM Electric lock OUTPUT (230 Vac 100 Wmax). Electric lock acting 2 sec. in advance of gate movement
15-14 SC-COM Open gate indicator light OUTPUT (24Vac 2Wmax). ON during the opening, pause and closing cycle
17-16 24Vac-COM Accessories power supply OUTPUT (24 Vac 300mAmax)
18-16 TST-COM Accessories power supply OUTPUT (24 Vac 300mAmax). Supplies power to the photocells when the TEST function is enabled
20-19 Foto1-COM External photocell (FOTO 1) INPUT (NC). Ignored during opening; during closing the direction of movement is reversed even without removing the obstacle
21-19 Foto2-COM Internal photocell (FOTO 2) INPUT (NC). During opening it generates a temporary stop until the beam is restored and then continues opening; during
closing it generates a temporary stop until the beam is restored and then opens
22-19 COS-COM Safety edge INPUT (NC) . During opening it generates a closing movement for approx. 3 sec. followed by a stop. During closing it generates an opening
movement for approx. 3 sec followed by a stop
23-27 F1A-COM Motor 1 limit switch for open position INPUT (NC)
24-27 F1C-COM Motor 1 limit switch for close position INPUT (NC)
25-27 F2A-COM Motor 2 limit switch for open position INPUT (NC)
26-27 F2C-COM Motor 2 limit switch for close position INPUT (NC)
28-33 AP-COM OPEN (NA) Input
29-33 CH-COM CLOSED (NA) Input
30-33 PP-COM Step-by-step INPUT (NA). Operating sequence: open-stop.-close-stop...after the control unit is switched on, the irst command is Open
31-33 PE-COM Pedestrian gate INPUT NA. Enables motor 2. The time of operation for opening is set by the trimmer A PED
32-33 ST-COM Stop INPUT NC. Generates the immediate stopping of movement in any position
34-35 2° CH Radio board 2
nd
channel OUTPUT
36-37 CALZA-CENT. Antenna INPUT for radio board
38-39-40 TF-TN-TR Autotransformer power supply OUTPUT
41-42-43 0-12-24 Voltages from transformer INPUT
44-45 0-12 Voltages from transformer INPUT
ADJUSTMENTS
TRIMMER T.LAV. To set the operating time from a minimum of 2 seconds to a maximum of 60 seconds; it is possible to double the operating time (dip N° 6 a ON)
TRIMMER T.PAUSA To set the closing delay time for motor M2 compared to motor M1, from a minimum of zero sec. up to a maximum of 20 sec.
TRIMMER RIT.2°M To set the pause time from a minimum of 0 seconds up to a maximum of 90 seconds and only active if automatic reclosing is set (dip N° 1 a ON)
TRIMMER A.PED To set the pedestrian gate opening time motor 2, from a minimum of 2 seconds up to a maximum of 60 seconds (dip N° 6 a ON)
ADJUSTMENT OF THE TORQUE
Adjustment of the torque through selectable four-setting autotransformer (1 minimum 4 maximum)
OPTIONS TO STANDARD OPERATION
DIP SWITCH N° 1: ON Enables automatic closing. After a complete opening cycle, when the PAUSE TIME set by the trimmer has elapsed, the gate closes automatically
DIP SWITCH N° 2: ON Closure after a blackout. After a blackout, the control unit automatically carries out the closing cycle
DIP SWITCH N° 3: ON Enables pre-lashing. The lashing light is activated 4 sec. prior to the start of movement
DIP SWITCH N° 4: ON Enables a longer courtesy light. The courtesy light output remains active for another 60 sec. after the end of movement
DIP SWITCH N° 5: ON Enables the release thrust. When the gate is fully closed, an open or step-by-step command generates an initial closing movement of the gates
before opening starts. This helps release the electric lock if necessary
DIP SWITCH N° 6: ON Enables doubling of the operating time. It sets the maximum operating time at 120 sec.
DIP SWITCH N° 7: ON The step-by-step command becomes shared. The step-by-step command usually only generates opening
DIP SWITCH N° 8: ON O Enables DEADMAN operation. The OPEN or the CLOSED key must be pressed continuously to carry out the movement
DIP SWITCH N° 9: ON When the gate is open, it closes again after 6 sec. Passing in front of FOTO 1. Passing in front of FOTO1 generates reclosing of the gate after 6
sec. with or without automatic closing enabled
DIP SWITCH N° 10: ON When the gate is closed, this allows opening even with the PHOTOCELL 1 darkened
DIP SWITCH N° 11: ON Change of operation of FOTO 1. Interruption of the beam during OPENING is ignored. Interruption of the beam during CLOSING generates a
temporary stop until the beam is restored, at which point the door or gate reopens
DIP SWITCH N° 12: ON Change of operation of FOTO 2. Interruption of the beam during opening is ignored. Interruption of the beam during closing generates a temporary
stop until the beam is restored, at which point the door or gate reopens
OPERATION SELECTOR TST TEST FOTO 1 ENABLED
The FOTO1 test checks that the photocell is working properly before every opening cycle. The tested photocells must be connected to terminal No. 18 TST at 24 Vac
R70 2AC