fi g. 1
A
fi g. 3
C
fi g. 5
E
fi g. 7
fi g. 9
INSTALLATION
B
fi g. 2
C
fi g. 4
D
fi g. 6
F
fi g. 8
SMOKE OUTPUT
KIKKA PLUS is designed for the connection of the fl ue at the
top, back or side left of the stove.
The stove is delivered ready for the ouput of the fl ue from the
back (fi g. 1).
FOR THE CONNECTION OF THE SMOKE OUTPUT
TO THE CHIMNEY, WHETHER FROM THE BACK,
SIDE OR TOP, IT IS NECESSARY TO REMOVE THE
CORRESPONDING METAL SIDE LEFT.
To connect:
- Remove the left metal side by the 3 screws on the back (B –
fi g.2)
At this point, choose the necessary fl ue connection.
REAR SMOKE OUTPUT CONNECTION
Fit the elbow joint to the smoke extractor unit vent (C- fi g. 4)
with the band provided.
Connect the side smoke output pipe (not provided) to the afore-
mentioned elbow joint.
In this case it is suffi cient to make the smoke output pipe (not
provided) pass through the hole in the lower part of the sheet
metal back.
SIDE SMOKE OUTPUT CONNECTION
Fit the elbow joint to the smoke extractor unit vent (C- fi g. 5)
with the band provided.
Connect the side smoke output pipe (not provided) to the afore-
mentioned elbow joint.
Remove the pre-cut diaphragm from the sheet metal side to al-
low the smoke output pipe (not provided) to pass through (fi g.
5).
Complete the operation by applying the closure rosette pro-
vided (D - fi g. 6) using the screws provided, after replacing the
metal side.
N.B. The rosette and the metal side must be fi tted after the fl ue
has been defi nitively fi xed.
TOP SMOKE OUTPUT CONNECTION
Remove the metal cover (E – fi g. 7)
Connect the rear smoke output pipe (not provided) to the
smoke extractor unit vent (F - fi g. 8) with the band provided.
AFTER COMPLETING THE CONNECTION OF THE
SMOKE OUTPUT PIPE TO THE FLUE, REPLACE THE
METAL SIDE.
- 36
-