Chimney Pot - EdilKamin IDROSALLY Instalación Uso Y Mantenimiento

Termoestufa de pellet
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 92
SMOKE OUTLET
The boiler-stove must have its own smoke outlet (the smoke
cannot be discharged into a smoke ue used by other devices).
The smoke is discharged through the 8 cm diameter outlet at
the back of the boiler
A T-junction must be set up with a condensation collection
stopper at the beginning of the vertical section.
The smoke outlet must be connected to outside by means of
suitable steel pipes EN 1856 certi ed.
All piping must be hermetically sealed and, if necessary, insu-
lated.
To seal the various elements of the piping together, materials
resistant to high temperatures must be used (silicon or mastics
for high temperatures).
The pipe must be hermetically sealed.
The material used to seal and if necessary insulate the pipes,
must be resistant to high temperatures (high temperature silico-
ne or mastic).
The only horizontal section allowed may be up to 2 m long.
It may have up to three 90° bends.
If the outlet is not tted into a chimney ue, a vertical section
and a wind guard are required (reference UNI 10683).
The vertical duct can be internal or external.
If the smoke channel (part of the pipe that goes from the boiler-
stove to the chimney ue) is outside, it must be appropriately
insulated. If the smoke channel is tted inside a chimney ue,
the latter must be suitable for solid fuel.
If it is wider than 150 mm in diameter it must be improved by
entering a pipe that has a suitable cross-section and is made of
suitable material (e.g. 80 mm diameter steel).
All sections of the smoke duct must be accessible for inspec-
tion. If it is not removable, it must have inspection holes to
allow for cleaning.
The boiler-stove is designed to operate under any weather
conditions.
In the case of particularconditions, such as strong winds, safety
systems may intervene that extinguish the thermo stove.
In this case, do not operate the appliance while the safety devi-
ces are disabled.
If the problem persists, contact the Service Centre.

CHIMNEY POT

The main characteristics are:
- an internal cross-section at the base, which is the same as that
of the chimney ue
- an outlet cross-section which is no smaller than twice that of
the chimney ue
- its position must be high enough to catch the wind and avoid
downdraft areas in turbulent wind..
INSTALLATION
TYPICAL EXAMPLES
Fig. 1
A: insulated steel chimney u, Insulated
B: minimum height 1.5 m, and however beyond the eaves of
the roof
C-E: air intake from outside (through section at least 80 cm²)
D: steel chimney ue inside existing masonry chimney ue
- 42
-
Fig. 2

Publicidad

Tabla de contenido
loading

Tabla de contenido