Important
When connecting, take care over the con-
nection of the neutral and earth wires; if
they are not connected correctly, the burn-
er does not light.

CONVERSION OF GAS SUPPLY

The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 23).
3 - Change the pilot light nozzle (see page 23).
4 - Adjust the minimum settings of the gas
control valves of the burners (see page
21).
5 - Remove the sticker from the nameplate and ap-
IT
ply the new one to identify the gas being used.
GB
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
DE
FR
ES
English
5 - Replace the control panel (D) and the knobs (B)
on completion of the operation.