5 - Connect the pressure gauge (E) to the pressure
test point (F).
6 - Turn the gas supply tap back on.
7 - Light the burner and turn the knob to the mini-
mum flame setting.
8 - Remove the minimum flame injector (G) and re-
place it with the one suitable for the type of gas
in use (see table at back of manual), screwing
it fully down.
9 - Slowly unscrew the injector (G) until the pres-
sure reading complies with the values in the ta-
ble (see back of manual).
10 - Check the stability of the flame.
11 - After making the setting, seal the screw with paint.
12 - Switch off the burner, turn off the gas supply tap
and disconnect the pressure gauge.
13 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
To carry out this operation, proceed as fol-
lows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Undo the screws (D) and extract the cap (E).
5 - Pull off the cone (F).
IT
6 - Clean the cone (F) and its seat.
7 - Coat the cone with grease (F), fit it in its seat
GB
and turn it a few times.
8 - Pull off the cone (F) to remove the excess
DE
grease.
9 - Replace the cone (F), the cap (E), the control
FR
ES
RECOMMENDATIONS FOR REPLACING PARTS
Before carrying out any replacement procedure, ac-
tivate all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the gas
supply tap, cut off the electricity supply using the
master switch and prevent access to all devices
that might cause unexpected health and safety haz-
ards if turned on. If worn parts have to be replaced,
English

GREASING THE GAS TAP

REPLACING PARTS

Liquid gas
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Remove the minimum flame injector (G) and re-
place it with the one suitable for the type of gas
in use (see table at back of manual), screwing
it fully down.
5 - After making the setting, seal the screw with
paint.
6 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
A
B
C
panel (C) and the knobs (A).
use original spare parts only. The manufacturer de-
clines all responsibly for injury or damage to com-
ponents due to the use of non original parts, or
extraordinary work on the appliance which may
modify the safety requirements without the manu-
facturer's authorisation. When ordering compo-
nents, follow the instructions provided in the parts
catalogue.