TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and malfunctions which might occur during
use.
Faults
Smell of gas.
The pilot light does not ignite.
The pilot light goes out.
The pilot light ignites but the burner
remains off.
The flame is yellow.
Burner control knob is stiff.
No water delivered.
FAULT
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
Causes
Occasional leak because flame has
gone out.
The spark ignition devices are not
working.
Air in pipelines due to long period
out of use.
The thermocouple has not warmed
up enough.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Gas valve malfunction.
Filler solenoid valve faulty.
Filling switch malfunction.
Well raised or not resting on fixed
part of appliance.
- 13 -
Remedies
Turn off the gas supply tap and
ventilate the room.
Check that the ignition devices are
in good working order
Light by hand with a naked light
Important
Contact the after-sales service
Make more attempts
to light the flame.
Make more attempts
to light the flame.
Check the condition
of the thermostat and
activate any ignition
enabling device.
Important
Contact the after-sales service
Important
Contact the after-sales service
Check the solenoid
valve connection
Important
Contact the after-sales service
Important
Contact the after-sales service
Check that the well is not raised or
not resting firmly on fixed part of
appliance.
6
IT
GB
DE
FR
ES
English