2 - Remove the knob (C).
3 - Undo the screws (D) and remove the control
panel (E).
4 - Undo the screws (F) to remove the lid (G).
5 - Connect the circuit-breaker (A) to the terminal
board (H) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
6 - Tighten the cable gland (L).
Important
When connecting, take care to connect the
neutral and earth lines.
CONVERSION OF GAS SUPPLY
The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap (A).
2 - Change the burner nozzle (see page 24).
3 - Change the pilot light nozzle (see page 25).
4 - Adjust the minimum setting on the gas control
valve (see page 21).
5 - If necessary, replace the primary air bushing of
the burner (see page 24).
6 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
F
H
7 - Fit the lid (G) and secure it with the screw (F).
8 - Replace the control panel (E) and the knob (C)
on completion of the operation.
A
- 19 -
G
L
IDM-39616001900.tif
IDM-39616002000.tif
IDM-3960200250.tif
English
IT
GB
DE
FR
ES