Maintenance; Impeller Replacement - Flotec FPSES2700A Manual Del Usuario

Ocultar thumbs Ver también para FPSES2700A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance

MAINTENANCE
Hazardous voltage. Can shock, burn, or
cause death. Before removing pump from basin for service,
always disconnect electrical power to pump and control
switch.
After removing basin cover and necessary discharge pip-
ing, lift pump out of basin.
Risk of electrical shock. Can burn or kill. Do
not lift pump by power cord. See "Lifting Pump" and
Figure 1, on Page 4.
Place pump in an area where it can be cleaned thoroughly.
Remove all scale and deposits on the pump.
Submerge complete pump in a disinfectant solution
(chlorox or similar strength chlorine solution) for at least
one hour before disassembling pump.
The pump seal plate contains a special lubricating oil
which should be kept clean and free of water at all times.

Impeller Replacement

To replace the impeller, follow steps 1 through 3. Reverse
the steps to reassemble the pump.
See the Repair Parts Illustrations for part identification.
1. Disconnect the power to the pump.
2. Remove the base and gasket.
3. Remove the impeller nut and washer; pull the impeller
off of the shaft.
4. Reverse steps 1 through 3 to reassemble the pump.
For parts or assistance, call Flotec Customer Service at
Capacitor Change
1. Disconnect the power to the pump.
2. Remove the motor cover from the top of the motor
assembly.
3. Remove the plastic capacitor box cover.
4. Remove the screw holding the capacitor tie-down
strap.
5. Remove the capacitor and cut the wires running to it.
6. Strip the wires for the new capacitor and install the
new capacitor. See Table 2 for capacitor specifications.
7. Reverse steps 1 through 4 for reassembly. Connect the
wires with the correct size wire nuts.
TABLE II
Capacitor
Model
Rating
FPSES2700A
45mF, 250V
Cord Replacement
1. Disconnect the power to the pump.
2. Remove the motor cover from the top of the motor
assembly.
3. Cut the cord wires in the top of the motor assembly.
4. Remove the cord clamp locking nut and pull the cord
out of the motor cover.
5. Insert the new cord through the hole in the motor
cover and clamp it with the locking nut.
6. Clip the motor leads as close as possible to the wire
nuts, strip the new cord leads and the motor leads, and
connect the new cord. Add new wire nuts.
7. Replace the capacitor cover, the motor cover, and the
motor cover O-Ring.
1-800-365-6832
5
Capacitor
Dimensions
45 x 71 mm

Publicidad

Tabla de contenido
loading

Tabla de contenido