Waeco DC-Kit4 Instrucciones De Montaje página 30

Set de ampliación para ccc
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
Using the DC Kit
I
NOTE
B2600, FJ1100, FJ1700, FJ2200, FJ2600, FJ3200: The remote
control for the roof air conditioner can only be used if the air con-
ditioning is supplied with 230 Vw mains network or with the
inverter.
Stationary mode: 230 Vw mains
The system is powered automatically via the inverter's integrated priority
circuit from the 230 Vw mains.
Driving mode: Power supply from the 12 V battery
➤ Switch on the inverter using the MCR-9 remote control.
A
NOTICE!
B3200, FJ1100, FJ1700, FJ2200, FJ2600, FJ3200: The
inverter may be damaged.
Do not switch on the roof air conditioner in the automatic or heat-
ing modes.
➤ Use the roof air conditioner as described in the operating manual.
Driving mode: power supply from the 12 V battery with motor
switched off
 B2600, FJ1100, FJ1700, FJ2200, FJ2600, FJ3200
If the inverter switches off due to low voltage in the supply battery
(10.5 V), no voltage will be supplied to the socket and the roof air
conditioner switches off. The inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's
activation point, the socket is supplied with voltage again.
You have to switch on the roof air conditioner again manually, as the
control electronics need to be reactivated after a lack of voltage.
 B3200
If the inverter switches off due to low voltage in the supply battery
(10.5 V), no voltage will be supplied to the socket and the roof air
conditioner switches off. The inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's
activation point, the socket is supplied with voltage again.
The roof air conditioner starts automatically.
30
DC-Kit4
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido