5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of "Table 1" and diagram.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the
open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole
disconnection from the power supply, with a contact opening of 3 mm.
1-2-3
Motor 1 encoder output
4-5
Motor 1 output
6 (+)
6-7
7 (-)
8 - N.O.
8-10
10 - Com
9 - N.C.
9-10
10 - Com
11 (-)
11-12
12 (+)
13 (+)
13-14
14 (-)
15
Aerial signal input
16
Ground aerial input
CON 1
Connection of motors metallic parts
CON 2
22 V ~ transformer power supply input
CON 3
Courtesy light output
Operating mode selection jumper:
J4 (jumper)
•
•
6 BASIC FUNCTIONS
After having installed the motor and made the elec-
tric connections and adjustments, it will be possible
to command the door directly using the keys on the
electric box.
22
Table 1 "terminal board connections"
Confi gurable 24V
output 1 max 5W (see P066 for values that can be selected)
Input 1 START. In case of intervention it provokes: the operator open-
ing or closing. It may operate as "inversion" mode (P049=0) or "step
by step" mode (P049=1).
Input 2 PHOTO 1. When enabled (see parameter P050 in the table),
activation of PHOTO 1 provokes: an inversion of direction (during clo-
sing), the arrest of the movement (during opening), prevent the start
(gate closed). If unused, short circuit.
24 V
power supply output for auxiliary devices max 200mA
Confi gurable 24V
output 2 max 5W (see P062 for values that can be selected)
(closed) = Normal functioning;
(open) = Programming mode;
Display
Key
If the installation requires different
commands and / or additional to the
standard, you can confi gure each in-
put to the required rate.
Refer to Chapter
"Advanced Programming".
Description
Causes the door to open if pressed.
Blocks movement during any manoeuvre if
pressed.
Causes the door to close if pressed.