CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the
correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do
not move or transport gas cylinders with the protection cap removed. Do not allow the electrode,
electrode holder, work clamp or any other electrically live part to touch a gas cylinder. Gas cylinders
must be located away from areas where they may be subjected to physical damage or the welding
process including sparks and heat sources.
Installation and Operator Instructions
Read this entire section before installation or operation
of the machine.
Location and Environment
This machine will operate in harsh environments.
However, it is important that simple preventative
measures are followed to assure long life and reliable
operation.
•
Do not place or operate this machine on a surface
with an incline greater than 15° from horizontal.
•
Do not use this machine for pipe thawing.
•
This machine must be located where there is free
circulation of clean air without restrictions for air
movement to and from the air vents. Do not cover
the machine with paper, cloth or rags when
switched on.
•
Dirt and dust that can be drawn into the machine
should be kept to a minimum.
•
This machine has a protection rating of IP23. Keep
it dry when possible and do not place it on wet
ground or in puddles.
•
Locate the machine away from radio controlled
machinery. Normal operation may adversely affect
the operation of nearby radio controlled machinery,
which may result in injury or equipment damage.
Read the section on electromagnetic compatibility in
this manual.
•
Do not operate in areas with an ambient
temperature greater than 40°C.
Duty cycle
The duty cycle of a welding machine is the percentage of
time in a 10 minute cycle at which the welder can
operate the machine at rated welding current.
Example: 60% duty cycle:
Welding for 6 minutes.
Refer to the Technical Specification section for more
information about the machine rated duty cycles.
Input Supply Connection
Check the input voltage, phase, and frequency of the
power source that will be connected to this wire feeder.
The allowable input voltage of the power source is
indicated on the rating plate of the wire feeder. Verify
the connection of grounding wires from the power source
to the input source.
Break for 4 minutes.
Gas Connection
A gas cylinder must to be installed with a proper flow
regulator. Once a gas cylinder with a flow regulator has
been securely installed, connect the gas hose from the
regulator to the machine gas inlet connector. Refer to
point 8 of the images below. The wire feeder supports
all suitable shielding gases including carbon dioxide,
argon and helium at a maximum pressure of 5,0 bar.
The Linc Feed also includes an internal gas flow
regulator, showed at point 11 of the images below.
Output Connections
Refer to item 3 of the images below.
Controls and Operational Features
1.
Water Connectors: Connections for water cooled
torches.
Warm water from torch.
Cool water to torch.
2.
Remote Control Receptacle: If a remote
control is used, it will be connected to the
remote receptacle.
3.
Euroconnector: Connect welding torches.
4.
Digital Display Interface: Control of welding
parameters including Wire Feed Speed, Voltage,
A-2