Appliance Installation; Discharge Direction - Thermador PROFESSIONAL SERIE Manual De Instalación Y Manteniemiento

Ocultar thumbs Ver también para PROFESSIONAL SERIE:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. For the most efficient air flow exhaust, use a straight
run or as few elbows as possible.
2. Do not use flex ducting.
3. COLD WEATHER installations should have an
additional backdraft damper installed to minimize
backward cold air flow and a non-metallic thermal
break to minimize conduction of outside temperatures
as part of the ductwork. The damper should be on the
cold air side of the thermal break. The break should be
as close as possible to where the ducting enters the
heated portion of the house.
4. Hood installation height above a cooktop or range can
vary. To obtain the necessary installation height above
a THERMADOR PROFESSIONAL
Range, consult the appliance's installation manual.
* For indoor grill installations, THERMADOR
recommends a minimum of 36" (914mm)
clearance and remote and inline blowers only.
5. Remote blowers require a five wire installation.
6. Make-Up Air: Local building codes may require the
use of make-up air systems when using ducted
ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to
locale. Consult your HVAC professional for specific
requirements in your area.

Appliance Installation

CAUTION:
Vent unit to the outside of building only. This unit
is only designed to be vented outside. It should
not be used for recirculation mode.
The hood can be mounted on a wall or suspended from a
cabinet. Both vertical and horizontal discharge are possible
with either mounting method.
Note:
Before installing the hood, the backsplash should be
installed first, if applicable.

Discharge Direction:

®
Cooktop or
®
The hood is shipped ready for vertical discharge. To
change to horizontal discharge, move the discharge cover
shown in Figure 2 to the top of the hood. The plate is held
in place by (4) screws.
This opening is
covered for
horizontal
discharge
This opening is
covered for
vertical discharge
Figure 2: 24" & 27" Pro Wall Hood Models
3
21
" (552mm)
/
4
Figure 3: Transition Cutout
English 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ph30hsPh36hsPh48hsPh36gsPh42gsPh48gs ... Mostrar todo

Tabla de contenido