Instructions for operation
Jet nozzles
8
Cleaning the ROLLJET nozzles
(VP and TS versions)
If the internal section of the jet nozzle does not
rotate, and therefore does not create the spiral
vortex massage effect, rotate the internal section
manually as shown in the fi gure. The nozzle
may not rotate if the appliance is not used for
long periods.
1
To dismantle the nozzles in order to remove
2
any impurities that may affect the operation of
the appliance, place the special tool against the
fi nishing surround of the nozzle and, pressing
inwards (1), turn the tool anti-clockwise (2).
Orienting and cleaning the FILLJET nozzles
(A900 MS version)
To orient the jets in the desired direction and thus
obtain a perfectly personalized massage, simply
turn the nozzle as shown in the fi gure.
To dismantle the nozzles in order to remove
1
any impurities that may affect the operation of
2
the appliance, place the special tool against the
fi nishing surround of the nozzle and, pressing
inwards (1), turn the tool anti-clockwise (2).
Routine maintenance
9
The shower box is built using materials which are
easy to clean and inhibit the build-up of bacteria
on the surface.
It is advisable to clean the appliance regularly, pre-
ferably using the specifi c products for each type of
operation; these products are available from our
authorized dealers and Service Centres.
If you prefer to use other products, the following
recommendations should be followed:
1) Stubborn stains can be removed using liquid
detergent or toothpaste (depending on the
type of stain) and rubbing gently with a soft
cloth.
2) To remove scale stains from the surface, use
lemon juice or vinegar (hot if possible) and
rub gently with a soft cloth.
No
No
3) Always use a soft cloth; never use abrasive
cleaning products (pads etc.).
4) Never use powder detergents. Always use
good-quality liquid detergents which contain
no alcohol or ammonia.
5) Never use acetone, ammonia or products
containing these substances, as these can
seriously damage the tub. Similarly, never
use products containing formic acid or for-
maldehyde.
(only for models with adjustable seat)
6) To clean the adjustable seat, use a good-qua-
lity liquid detergent. Do NOT use products in
powder form, nor products containing bleach
or ammonia.
Uso box MyTime - Code 10009370 - Edition 3 - 12/2005
Washing cycle
If the hydromassage functions are left unused
Cleaning the inter-
for long periods, it is advisable to wash out all
nal hydromassage
the tubes and pipes in the shower box, including
components
those for the Turkish bath, in order to maintain
the effi ciency of all the circuits.
To start the cycle, turn on the tap and hold down
the "+" and "–" keys simultaneously until the
display shows "30", which indicates the number
of seconds to elapse before the start of the cycle
(countdown).
At the end of the 30 seconds, which is more than
enough to allow you to exit the box and close the
door, all the illuminated dots on the keyboard will
begin to fl ash and the cycle will start.
At the end of the cycle the keyboard will return
to "standby" mode.
The cycle can be interrupted at any time by
pressing any key on the keyboard.
Remember that the wash cycle can be activated
only if the tapware is positioned in such a way
as to enable the keyboard.
(see paragraph 2 - "Using the Digital Con-
trols").
This function can also be used to pre-heat the
tubes and therefore avoid the unpleasant surprise
of jets of cold water.
AT LEAST ONCE YEARLY
It is not necessary to switch off the water supply
to the shower box in order to clean the fi lter,
since a special internal cut-off device discon-
nects the water supply when the fi lter housing
is opened.
(A1100 and R128 only)
1
To access the fi lter compartment, it is necessary
to remove the seat from the column temporarily.
Proceed as follows:
1) Pull the lever and move the seat downwards
2) Pull the knob (located behind the seat) fi rm-
3) Lower the seat completely and remove.
Important: Hold the seat fi rmly and lay it
gently on the shower tray.
2
(Models without adjustable seat)
To access the fi lter compartment, it is necessary
to remove the backrest temporarily.
To remove the fi lter cap, use the special tool
contained in the hardware bag, or simply a coin.
If the cap is diffi cult to remove, a large fl at-head
3
screwdriver may be used.
Unscrew the cap completely, remove from the
V
housing and wash under a tap.
ERSIONS
A1100
Any scale build-up may be removed by immer-
R128
AND
sing the fi lter in a solution of water and vinegar
for 3 - 4 hours. Alternatively, one of the de-scaling
V
ERSIONS
products commonly used for steam irons or cof-
WITHOUT SEAT
fee-makers can be used. Follow the instructions
and the concentrations recommended by the
manufacturer of the product used.
1
4
13
almost to the lowermost position.
ly.
5
6
English