Beninca DA.24A Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
Trimmer A
Trimmer B
Power setting
-
+
Trimmer A
Trimmer A: it adjusts the intervention time of stop and electronic power limiter.
By turning it counterclockwise the circuit is more sensitive (a light effort is enough to stop the movement),
on the contrary, by turning it clockwise the circuit becomes less sensitive and a great effort is necessary
to stop the motor. Adjust according to the standards in force.
Trimmer B: it adjusts the movement speed of the automation during the working cycle; by turning it coun-
terclockwise the speed diminishes. Adjust according to the standards in force.
Trimmer C: it has the same function as the trimmer B as far as the braking cycle is concerned.
Trimmer D: it adjusts the pause length between the opening and closing when the automatic closing func-
tion is inserted. By turning it counterclockwise the time diminishes (min. 7 s); by turning it clockwise the
time increases (max. 140 s).
Trimmer E: it adjusts the length of the closing delay of the 2nd motor; by turning it clockwise the time
increases (from 1 to 10 s).
Opening delay of the 2nd motor is fix and it is of 3 s.
Automatic closing
Opened Dip-fix 1: automatic closing function active.
Closed Dip-fix 1: automatic closing function not active.
Condominium function
Opened Dip-fix 2: condominium function not active.
Extension work time
Opened Dip-fix 3: max. work time 180 s.
Closed Dip-fix 3: max. work time 90 s.
Settings and selections
Trimmer C
Trimmer D
Cycle speed
regulation
Braking speed
regulation
-
+
-
Trimmer B
Trimmer C
Dip fix 2
Condominium
function
Dip fix 1
Automatic
closing
Open: Actived
Trimmer E
Closed: Disactived
Pause time
regulation
+
-
+
Trimmer D
Open: Disactived
Closed: Actived
Dip fix 3
Extension of
work time
Open: Actived
Closed: Disactived
Closing delay 2nd
motor regulation
-
+
Trimmer E
9

Publicidad

Tabla de contenido
loading

Tabla de contenido