2. Check that the battery is free from defects, in
good condition and is the correct type for the
battery charger.
3. Check that the battery is properly connected
and that the battery fuse, if any, is not broken.
4. Check that the mains voltage is right and that
there are no blown fuses.
Safety shut-off
Charging is terminated if:
• The recharged number of ampere hours
exceeds the preset value.
• The charging time for any of the charging
phases exceeds the preset value.
• Voltage and current exceed the maximum set
value.
• The battery is disconnected without the battery
charger being stopped.
Charging is temporarily stopped or reduced when:
• The battery charger temperature exceeds
charger limits.
Checking error messages
When the battery charger detects a fault:
• the alarm indicator is lit on the battery charger
control panel. See Fig. 1 pos 2.
Make a note of the information in the error
messages and call service technician.
8
Technical data
Ambient temperature
1
: 0 - 40 °C (32 - 104 °F)
Storage temperature: –25 - 60 °C (–13 - 140 °F)
Mains voltage: See data label
Power: See data label
2
Efficiency: >90% at full load.
Ingress protection: IP20
Approval: CE and/or UL. See data label
1) Measured at the charger air inlet.
2) Located on the left or lower side of the charger.
Recycling
The product is recycled as electronic scrap. Local
regulation apply and should be followed.