Connecting the power
m
WARNING
Electrical Shock Hazard
– Plug into a grounded 3 prong outlet.
– Do not remove ground prong.
– Do not use an adapter.
– Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
The appliance comes with a 3-wire power supply cord,
UL listed in the USA.
The appliance requires a 3-wire receptacle.
The receptacle must be installed by a licensed electrician
only.
The socket must be fused with a 10 to 16 A fuse. Please
observe in this coherence the following table:
Appliance
BottomFreezer 36"
Orient ground prong to the bottom as shown in the pictures.
For the installation position of the receptacle see "Installation
dimensions", page 10.
Additional grounding procedure
Some local regulations may require a seperate ground.
In such cases, the required accesseory ground wire, clamp
and screw must be purchased seperately.
Never ground the appliance to plastic plumbing lines,
gas lines or water pipes.
m
MAX load at one time
6.0 Ampere
Grounding instruction
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for the
electric current
m
WARNING
Improper connection of the equipment grounding
conductor may result in electric shock. Have the
appliance checked by a qualified electrician or service
technician if you are in doubt as to whether the
appliance has been properly grounded.
Connecting the water
m
CAUTION
Only connect the appliance to drinking water!
A cold water connection is required for operation of the
automatic ice maker. The water pressure must be between
25 and 120 psi. (1.72-8.25 bar). The installation must comply
with local plumbing regulations.
A separate shut-off valve must be installed for the appliance
water connection.
The shut-off valve for the water connection must not be
behind the appliance. It is recommended to place the shut-
off valve directly next to the appliance (base unit) or in
another easily accessible location.
When installing the water connection, observe the permitted
installation areas for the pipe. For the permitted installation
areas and dimensions see "Installation dimensions",
page 10.
The supply pipe can be located at the side on the right (a), at
the side on the left (b) or underneath (c).
Maximum outer diameter of the water pipe
13
(without fittings):
/
" (10 mm).
32
Attach a separate shut-off valve for the water connection
in a suitable, easily accessible location.
Do not use a self-piercing valve!
m
m
9