located and clean properly can ensure ignition
and optimal operation of your thermostove.
When positioning the crucible, carefully check
that the ends of the pads completely adhere to
their home and that the hole with pipe dedicated
to the passage of the resistance.
There should be no residual combustion in the
contact zone between the edges of the crucible
and the support surface on the door crucible.
The decreased or absent cleaning
can cause misfire and cause dam-
age to the thermostove and the en-
vironment (possible emissions of
soot and unburned). Do not pour the pel-
lets may be present in the brazier to mis-
fire.
Cleaning exchanger - stove off
Fouling act as insulation and the thicker they
are, the lower the heat that is transmitted to the
water and to the structure
very important to perform the cleaning of the
tube bundle, said exchanger also, to prevent the
fouling of the same and prevent clogging and
jamming of the cleaning
quickly for 5-6 times the lever so that the springs
can remove the soot deposited on the pipes.
Check every 2/3 days
Cleaning the ash collection compartment.
Clean and empty the ash tray being careful with
hot ash. The ash must be completely cold for a
vacuum cleaner to be used to remove it. Only if
the ash is completely cold, you can also use a
canister vacuum cleaner suitable for picking up
particles of a certain size.
54
generally.
Therefore
device.
Pull and push
Cleaning ash and combustion chamber in-
cluding the spark plug lead
Cleaning Flame beater
Cleaning the glass
For cleaning the ceramic glass, the use of a dry
brush is recommended, or if it is very dirty, the
special spray detergent, applying a small quan-
tity then cleaning with a cloth.
Do not use abrasive products and
do not spray the cleaning product
on the glass of the painted parts or
on the gaskets of the fire door (ce-
ramic fibre cord).
Cleaning of stainless steel and satin-finish
surfaces
Normally these surfaces do not need to be treat-
ed, but if they do, avoid cleaning them with abra-
sive materials. For surfaces in stainless and sat-
in brushed steel we recommend cleaning with
a paper towel or a clean dry cloth moistened
with a detergent based on non-ionic surfactants
(<5%) A spray glass cleaner may be used.
Avoid contact with skin cleanser
and eyes. In case this happens,
sprinkle with plenty of water and
contact the nearest medial center.
Cleaning of painted pats
Do not clean the painted parts with wet rags
when the unit is in operation or hot to prevent
thermal shock to the paint which may cause it
to detach. Do not use abrasive or aggressive
products or materials. Clean with damp cot-
ton or paper towels. The silicon paints used by
manufacturer possess technical characteristics
that make them resistent to very high tempera-
tures. There is however a physical limit (380° -
400°) beyond which the paint begins to fade or
(over 450°) to vitrify; it may then flake and detach
from the steel surface. If this happens, it means
that temperatures have been reached that are
far above those at which the unit should operate
properly.