Here follows a table with all available commands.
Name
Message
NAM
*?NAM<cr>⇒
VER
*?VER<cr>⇒
*BEP<cr>
BEP
*USRtext<cr>
USR
*?USR<cr>
*STOnn<cr>
STO
RCL
*RCLnn<cr>
*FRQnn...n<cr>
FRQ
*?FRQ<cr>
*ATTnn<cr>
ATT
*?ATT<cr>
ERN
*?ERN<cr>
ERC
*ERC<cr>
*?ERLnn<cr>
ERL
*?LCK<cr>
LCK
*MIHd<cr>
MIH
*?MIH<cr>
*MILd<cr>
MIL
*?MIL<cr>
*MBWd<cr>
MBW
*?MBW<cr>
Page 26
Answer
⇐*NAMMO-170<cr>
⇐*VERv0.7.10<cr>
*USRtext<cr>
*FRQnn...n<cr>
*ATTnn<cr>
*ERNnn...n<cr>
*ERLtext<cr>
* LCKchhhh <cr>
*MIHd<cr>
*MILd<cr>
*MBWd<cr>
USER'S MANUAL. MO-170
Description and Format
Retrieve equipment model
Retrieve SW version.
Acoustic indication
Set a new USER text to be displayed in the LCD
panel.
'text' is an ASCII text with a maximum of 32
characters
Returns the current USER text
Save the current configuration to a memory.
´nn´ is a decimal value from 00 to 10
Retrieve a configuration from a memory.
´nn´ is a decimal value from 00 to 10
Modify the equipment RF frequency.
´nn...n´ is the frequency value in Hz, expressed
with 9 digits, from 45 to 875 MHz
Returns the current RF frequency in Hz and with
9 digits (padding with '0' on the left).
Change the RF output attenuation.
'nn' is the new decimal attenuation value in dB
Returns the current RF attenuation value.
'nn' value using 2 decimal digits
(padding with '0' on the left)
Retrieve the internal error counter.
'nn...n' value using 8 decimal digits
(padding with '0' on the left)
Clear the internal error counter.
Retrieve an error message
'nn' is the error index in decimal value 'text' is
the text string in ASCII format
Retrieve the locked status.
'c' is the lock test result: 'L for locked, 'U' for
unlocked
'hhhh' is an hexadecimal value corresponding
to a status code (see section 4.11 for error
codes)
Sets the modulator HP TS Input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI 3:TEST
Asks for the current modulator HP TS input. 'd'
as before
Sets the modulator LP TS input
'd' decimal digit
0:ASI1 1:ASI2 2:SPI 3:TEST
Asks for the current modulator HP TS input. 'd'
as before
Sets the modulator output BW
'd' decimal digit
0: 8MHz, 1: 7MHz, 2: 6MHz
Asks for the current modulator output BW. 'd' as
before