1. SELECT BLOWER OPTION AND INSTALLATION TYPE
Either an interior or an exterior blower or in-line blower may be used with this hood. The Best IP29M Series must be installed with blower
models iQ6, P3, P6, iQ12, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers
sold separately.)
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 9, 11 to 15, 18 and up of this
manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct joints.
NOTE: It is recommended that there be a minimum of 6" of straight duct from this hood to an elbow for 8" ducting and 12" for 10" ducting.
ROOF CAP
DECORATIVE
FLUE
12", 18", 24" or 30"
(305, 457, 610 or 762)
or TRIM
HOOD
30" TO 36" (762 to 914)
ABOVE COOKING SURFACE
NOTE: Dimensions in ( ) are in mm.
HH0165A
MODEL iQ6, P3 OR P6
SINGLE INTERIOR BLOWER
TYPICAL DUCTWORK
DECORATIVE
FLUE
12", 18", 24" or 30"
(305, 457, 610 or 762)
or TRIM
HOOD
ABOVE COOKING SURFACE
NOTE: Dimensions in ( ) are in mm
HH0082A
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER
TYPICAL DUCTWORK
8" (203) ROUND DUCT
EXTERIOR
BLOWER
10" (254)
ROUND DUCT
30" TO 36" (762 to 914)
DECORATIVE
FLUE
12", 18", 24" or 30"
(305, 457, 610 or 762)
or TRIM
HOOD
30" TO 36" (762 to 914)
ABOVE COOKING SURFACE
NOTE: Dimensions in ( ) are in mm.
HH0166A
MODEL iQ12 OR P12
DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
10" [254] ROUND DUCT
(except ILB3, 8'' [203] ROUND DUCT)
IN-LINE BLOWER
DECORATIVE
FLUE
12", 18", 24" or 30"
[305, 457, 610 or 762]
or TRIM
30" TO 36" [762 to 914]
ABOVE COOKING SURFACE
NOTE: Dimensions in [ ] are in mm.
HH0083A
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER
TYPICAL DUCTWORK
5
ROOF CAP
10" (254) ROUND DUCT
ROOF CAP
WALL
CAP
HOOD