Best IP29M Serie Instrucciones De Instalación página 9

Ocultar thumbs Ver también para IP29M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. INSTALL BLOWER HOUSING
Use both screws (A) previously removed in step 4 to assemble the blower housing to the mounting brackets. For installation with decorative
flue cover AEIP Series only, place 4 nuts (B) (from flue cover parts bag) on the pem studs, leaving 1/4" for the hood installation. The blower
housing must be installed in such a way that its label (C) will be on the same side as the hood control side. See illustrations below.
I
NSTALLATION WITH DECORATIVE FLUE COVER
B
HD0230
9. SECURE BLOWER HOUSING TO BRACKETS
From the inside, secure the blower housing to mounting brackets, using 2 no. 8 x 3/8" screws
per side.
Screws must be installed in embossed sections, see details at right.
10. INSTALL 8" ROUND ADAPTER AND DAMPER TO ROUGH-IN PLATE
(iQ6, P3 OR P6 INTERIOR BLOWERS ONLY)
Attach transition to iQ6, P3 or P6 blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.
11. INSTALL THE ROUGH-IN PLATE IN THE BLOWER HOUSING
Run power cable to installation location. Refer to the instructions included with
the selected blower/rough-in kit (sold separately) for details on installing the
rough-in plate. Install the rough-in plate so that the wiring box is located on the
right side when facing the hood, as specified on the blower housing label.
Connect adapter/damper or rough-in plate (according to blower model) to
ductwork. Use metal duct tape to make all joints secure and air-tight.
AEIP S
C
B
A
I
ERIES
NSTALLATION WITH DRYWALL TRIM
HD0231
HD0232
9
ATDIP S
C
A
R
ETAINING SCREWS LOCATION
HO0100
HO0196
W
IRING COVER
L
OCK NUTS
ERIES

Publicidad

Tabla de contenido
loading

Tabla de contenido