Manual Start And Stop; Pump Speed Setting; Timeclock Setup And Operation - Jandy Pro Series JEP-R Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PAGE 12
ENGLISH
3.5

Manual Start and Stop

Up to eight (8) speeds may be started from the
controller. Manual operation of speeds "eStar" through
"4" differs from manual operation of speeds "5" through
"8".
NOTE When starting the pump, the pump will first run
at the priming speed for the priming duration, as
set by the installer.
Speeds eStar through 4
To start the pump manually running at speeds
"eStar" through "4", press button "
corresponding to the desired speed. The associated LED
will light red and the controller enters the
10:00AM
2
To stop the pump, press the button again. The associated
LED will extinguish and the pump and controller will
return to the
mode.
OFF
Speeds 5 through 8
To start the pump manually at speeds "5" through
"8", press the
button. The controller displays
MENU
SELECT PRESET/N:LABEL
number and label of the last selected speed "5" through
"8".
Using the arrow keys, select the desired speed to
activate, and then press
MENU
starting the pump running at the selected speed.
SELECT PRESET
2
MENU
To stop the pump, press
MENU
the pump, press any button "
3.6

Pump Speed Setting

With the exception of preset "
adjusted while the pump is running in that speed mode.
Preset "
" is reserved for the eStar function, and its
speed is set by the installer.
JEP-R Variable-Speed Pump Controller
" through "4"
mode.
RUN
2:SPEED 2
RPM: 1200
3
4
MENU
, where n:label is the
to enter
mode,
RUN
5:SPEED 5
3
4
. To exit without starting
" through "4".
", each speed may be
|
Installation Manual
To adjust the pump speed, the controller must be in the
mode. While in
RUN
RUN
the pump speed. Adjust the speed by pressing the up or
down arrow keys. The speed is saved by the controller
and will remain until changed again.
NOTE Pump speed is adjustable only within a certain
range. The minimum and maximum limits of the
range are set by the installer.
NOTE When used with a solar heat system, set speed
to at least 3000 RPM and potentially up to 3450
RPM, based on the pump's head required to
push the water up a minimum of 12-15 feet.
10:00AM
3.7

Timeclock Setup and Operation

NOTE
The controller has a non-replaceable battery back-up
that keeps time, programs, and speed settings when power is
disconnected and should never require replacement.
The controller allows the user to create timed pump
programs on pump speeds (presets) "
two timers operate independently of each other, and may
overlap in time if desired.
Timeclock Setup
Start the desired speed, "
controller enters the Timeclock setup mode. Using the
arrow keys, select
ON TIME
desired pump turn-on time using the arrow keys and
press
. The time is stored. Select
MENU
the arrow keys and press
turn-off time using the arrow keys and press
time is stored.
2:SPEED 2 TIMECLOCK
Using the arrow keys, select
using the arrow keys. The program is now
ENABLE
enabled to run. Press the speed button ("
return to the
mode.
RUN
mode, the controller displays
2:SPEED 2
RPM: 1400
" and "2". The
" or "2". Press
. The
MENU
and press
. Set the
MENU
OFF TIME
. Set the desired pump
MENU
MENU
ON TIME
. Select
TIMECLOCK
" or "2") to
using
. The