Front Panel Layout; Thermal Protection - Solter SolCUT-40 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FRONT PANEL LAYOUT

1 - Power Indicator.
2 - Termic Protection Indicator.
3 - Current Regulation (A)
4 - Negative dinse socket
5 - Torch connector.
6 - Indicator compressed air.
7 - Power Switch.
8 - Power cable.

THERMAL PROTECTION

During prolonged use at maximum power, the equipment will stop on reaching maximum temperature
values and the amber pilot light will come on. The fan will continue to function in order to cool the ma-
chine, and in a few minutes the equipment will start again.
INSTALATION
The machine must be installed by qualified personnel. All connections must be made in compliance
with current safety standards and full observance of safety regulations.
If the system air contains a considerable amount of moisture and oil, it is best to use a drying filter to
avoid excessive oxidation and wear of the consumer parts, damaging the torch and reducing the cut-
ting speed and quality.
If the air supply comes from a pressure regulator of a compressor or centralized system, the regulator
must be set to an output pressure of no more than 8 bar (0,8 Mpa). If the air supply comes from a
compressed air cylinder, the cylinder must be equipped with a pressure regulator.
Never connect a compressed air cylinder directly to the regulator on the machine! The pres-
sure could exceed the capacity of the regulator, which might explode'