ELECTROMAGNETIC DISTURBANCES
Electromagnetic interferences produced by welding equipment may interfere in the operation
of equipment which is sensitive to this kind of interference (computers, robots etc).
Ensure that all the equipment in the welding area is resistant to electromagnetic radiation.
In order to reduce radiation as much as possible work with welding wires as short as possi-
ble, placed in parallel on the floor if possible. Work at a distance of 100 metres or more from
equipment which is sensitive to disturbances. Ensure that the machine equipment is cor-
rectly earthed. If there are interference problems despite having taken the above described
precautionary measures, the operator must take extra measures such as moving the welding
machine, and the use of filters or protected cables to ensure that interference with other
equipment does not occur.
RECYCLING
In compliance with European Directive 2002/96/EC on waste electric and electronic equip-
ment this equipment must be deposited in your local recycling centre at the end of its useful
life.

GENERAL DESCRIPTIONS

Welding equipment which uses INVERTER technology comprises an electric circuit in which all the
components are inserted. The equipment functions at a frequency of 70 KHz which permits an opti-
mum arc starting as well as a constant weld.
TECHNICAL DATA
IEC 974
EN 60974
S/N....
MMA
TIG
UO
X
I
U
U1
50/60 Hz
I
IP21
S
ELECTRICAL INSTALLATION
Electrical installation should be carried out by qualified personnel in compliance with the laws of the
country where the installation is being made. The machine must be connected to an electrical panel,
which must consist of a differential switch and an automatic switch. The differential switch protects
people from direct or indirect contact with electrical parts. The automatic switch must be chosen with
respect to the characteristics of the equipment. We recommend a slow type intensity-time switch
(Curve D), to prevent accidental discharges.
The yellow/green wire of the mesh MUST be connected to the earth conductor. Never use this
SOLTER
SOLDADURA S.L.
This equipment has been constructed in keeping with this regulation.
International regulation for the construction of this equipment.
Serial number.
Welding using coated electrodes
TIG welding process.
Secondary electric voltage in vacuum.
Service factor %.
Welding current (A).
Secondary current with a welding current of I2.
Nominal supply current.
50Hz-60Hz single phase supply
Current absorbed into the corresponding welding current of I2.
When the TIG process is used divide by 1.6.
Equipment external protection grade.
Apt for work in high-risk locations.
Use only safety regulation approved plugs and sockets.
conductor as a power socket.