DIP 1
"P.P. Mod"
DIP 2
"C.A."
DIP 3
"Cond."
DIP 4
"Prelam."
Note: After modifying the setting of trimmers and Dip-Switches, switch off and power the unit again.
TCA
The automatic closure time can be adjusted with this trimmer. Check Dip-switch N°2= On.
This function can be adjusted between 1 s minimum and 125 s maximum
TL
The maximum time of the opening and closing phases can be adjusted with this trimmer.
Time should be preset approx. 4 sec. longer than the actual stroke time of the automatic system.
Adjustment ranges from 5 s minimum to 130 s maximum
Note: In the event of partial opening/closing, the control unit calculates the remaining time to
complete the operation in order to avert useless overheating of the motor.
TRAC
It allows to adjust the delay time with which motor MBE starts closing with respect to motor MB.
Adjustment range from 3 s minimum to 30 s maximum. During opening, the out of phase time of the
motors is 2 seconds.
The control unit is complete with an incorporated radio receiver for both fixed-code and variable code radio
controls, at 433.92MHz frequency.
To use a radio control, its code should be copied first. The memorization procedure is shown here under. The
device is able to store up to 14 different codes in memory.
Memorization of a new transmitter with activation of the P.P. (step-by-step) function
- Press PGM button once for 2 seconds, the D4 LED starts flashing rapidly.
- Within 10s, press the transmitter push-button which should be stored in memory with P.P. function.
To delete the control unit codes from memory
- Cut-off power supply to the control unit
- Reset power supply by keeping the PGM button pressed for 5 seconds; the D4 LED switches on with fixed
light and then off when deletion is completed.
- Release the PGM button, memory is deleted and the D4 LED starts flashing regularly again.
NOTE: If the D4 LED switches on with two long flashes and then switches off, when entering the transmitter
codes memorization mode, this means that the receiver is full and no other transmitter code can be stored in
memory.
LED functions
LED D2
Access when the unit is powered
LED D4
Radio receiver programming
LED D5
This LED switches on when radio signals are received on the built-in module frequency.
Dip-Switch functions
The operating mode of "Pulsante P.P." (Step-by-step push button) and of the transmitter
is selected.
Off: operation : APRE > STOP > CHIUDE > STOP >
On: operation: APRE > CHIUDE > APRE >
Automatic closure is enabled or disabled.
Off: disabled automatic closure
On: enabled automatic closure
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the
transmitter have no effect in the opening phase.
Forewarning flashing light enabled or disabled
Off: disabled forewarning flashing light
On: enabled forewarning flashing light. The flashing light is activated 3 s before the motor
starts.