G
B
fill in approximately 0.35 l engine oil (15W40 above 0
0
5W30 below 0
C) up to the upper mark of the oil dipstick
(fig. 7/pos. 16) by using the supplied oil funnel (fig. 3/pos.
21).
Caution! Prior to commissioning the device for the first
time, engine oil and fuel must be filled into the respective
reservoirs.
5. Operation
Check fuel level and refill, if required
Ensure the device is sufficiently ventilated
Make sure that the ignition cable is attached to the
spark plug
Check the immediate surroundings of the generator
Disconnect any electrical device which might be
connected to the generator

5.1 Starting the motor

Caution! Do not use chemical starting aids such as
easily volatile fuels or similar.
Turn the ventilation on the tank lid to "ON" (fig. 4/pos. A).
Turn the selection switch (fig. 1/pos. 3) to "Choke".
Start the engine by means of the starter pull cord handle
(fig. 1/pos. 4). In order to do this, pull the handle strongly.
If the engine does not start, pull the starter pull cord
handle once again. Caution! Always pull out the starter
pull cord handle slowly until first resistance before it is
pulled out quickly for starting. Do not let the starter pull
cord handle fly back following a successful start.
Turn the selection switch (fig. 1/pos. 3) to the "ON"
position after 15 to 30 seconds.
0

5.2 Energy saving mode:

C
Econ switch (fig. 1/pos. 9) to "I":
The rotational speed of the engine is regulated
depending on the load. Thus, the device runs at a very
low volume and low consumption.
Econ switch (fig. 1/pos. 9) to "0":
The generator runs continuously at the maximum
rotational speed of the engine.
5.3 Loading the generator
Connect 230 V~ devices to be operated to the power
socket (fig. 2/pos. 10).
Caution! This socket may be powered continuously with
1600W.
Connect 12 VDC devices to be operated to the 12 VDC
connection (fig. 2/pos. 12) by means of an adapter cable
(fig. 3/pos. 20).
Caution! The 12 V connection may be loaded with max.
100 W.
Caution! The 12 V connection may only be used if the
Econ switch is set to "0".
Do not connect the generator to the domestic power
network. This may damage the generator.
Note: Some electric devices (jigsaws, drills, ...) may
have a higher power consumption if they are used under
heavy-duty conditions. Make sure that you do not exceed
the power output of the generator.

5.4 Overload protection

230 V power socket:
Operation indication (fig. 2/pos. 14) lights in green
during normal operation.
When overloaded, the overload indication (fig. 2/pos.
13) flashes red.
Turn the selection switch (fig. 1/pos. 3) to the "OFF"
position. Repeat the starting procedure according to
capital 5.1.
Caution! If this is the case, make sure that the output