5 Operation
6 Error messages
You can access the timer programme for the circulation
pump by pressing programming button P and turning
the dial until the pump symbol appears in the display in-
stead of the water tap symbol. The setting of the desired
heating times is done in the same manner as for the set-
ting of the heating times for the reheating function
(see 5.5.3). Set the timer programme so that the circula-
tion pump only runs at times when a demand for hot
water is expected. Otherwise the circulation pump will
be running unnecessarily and will thus cool down the
cylinder little by little.
5.6
Activating the special functions
Display
Required steps
Advance function
Press the Special function button once -
the advance symbol in the display blinks
for approx. ten seconds, then the func-
tion is activated.
The function is deactivated automatically
on reaching the next reheating window.
To deactivate the function beforehand,
you merely have to reselect the function.
This function can only be activated in re-
heating mode
One-time reheating
Press the Special function button twice -
the one-time reheat symbol in the display
blinks for approx. ten seconds, then the
function is activated.
To deactivate the function beforehand,
you merely have to reselect the function.
Holiday function
Press the Special function button three
times - the Holiday function symbol in
the display blinks for approx. ten sec-
onds, and you can use the dial to set the
number of holiday days.
The function is then activated for the set
time.
To deactivate the function beforehand,
you merely have to reselect the function.
If the anti-Legionella function is activat-
ed, it is carried out on the last day of the
holiday.
Table 5.6 Activating the special functions
12
.
6
Error messages
In the event of temperature sensor faults, the
auroMATIC 560 solar controller displays error messages
in the main operating level.
The sensor configuration is always determined when the
unit is started up, e.g. after the power supply has been
switched off and on again. Depending on the hydraulic
plan that has been set, the controller detects whether a
fault is present or whether a particular sensor is not re-
quired for operation.
a
Caution!
Never attempt to perform maintenance or re-
pairs on your equipment by yourself. Assign an
approved qualified servicing company with this
work. We recommend taking out a maintenance
agreement for your solar installation with your
approved qualified servicing company.
The following table explains the meanings of the mes-
sages.
Display
Message/Meaning
Cylinder sensor 1 error
This error appears if the connected sen-
sor is faulty.
Cylinder sensor 2 error
This error appears if the connected sen-
sor is faulty or if the sensor is absent.
Cylinder sensor 3 error
This error appears if the connected sen-
sor is faulty.
Table 6.1 Error messages
There are no error messages for collector sensors Col 1
and Col 2. A plausibility check is possible, however, e.g.
by comparing the collector temperature with the outside
temperature.
Operating Manual auroMATIC 560 0020060907_00