Display
Setting by turning the dial
Set the activation difference for Cylinder 1
(The activation difference should always be
2 K greater than the deactivation difference)
Set the deactivation difference for Cylinder 1
(The deactivation difference should always be
2 K less than the activation difference)
Set the maximum temperature for Cylinder 2 20 - 90 °C
Table 6.1 System parameters (continuation)
a
Caution:
The maximum permissible temperature for the
installed cylinder (MAXT 2) must not be ex-
ceeded.
Display
Setting by turning the dial
Set the activation difference for Cylinder 2
(The activation difference should always be
2 K greater than the deactivation difference)
Set the deactivation difference for Cylinder 2
(The deactivation difference should always be
2 K less than the activation difference)
PRIO
Cylinder with highest priority
FROS:
Frost protection function
Table 6.1 System parameters (continuation)
Installation Manual auroMATIC 560 0020060907_00
Setting range
2 - 25 K
1 - 20 K
Setting range
2 - 25 K
1 - 20 K
1, 2
-5 °C – 10 °C; OFF
Start-up 6
Default setting
7 K
3 K
60 °C
Default setting
7 K
3 K
1
OFF