Descargar Imprimir esta página

DITEC E1 Manual De Instalación página 12

Tablero electrico para automacion a un motor con radio incorporado

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
1.2 Outputs and accessories
GB
Output
1
+
0
-
11 24 V= / 3 W (0,125 A)
1
12 24 V= / 3 W (0,125 A)
1
24 V= / 120 mA max
1
11-12
U
W
V
M1
230 V~ / 100 W (0,4 A)
W
N
230 V~ / 100 W (0,4 A)
C
N
2.
SETTINGS
2.1 Trimmer
Trimmer
TM
60 s
MIN=10 s
MAX=120 s
TC
120 s
MIN=0 s
MAX=disabled
RF
MIN
MAX
R1
MAX
MIN
E1 - IP1853
Value
Accessories power supply. Power supply output for external accessories, including
24 V= / 0,5 A
automation status lamp.
Automation open lamp. Only with the limit switch 0-11 (N.C.) connected and DIP2=OFF
will the light switch off when the automation is closed.
Automation closed lamp. With DIP2=ON, the light switches off when the automation
is open.
Automation closed lamp. Only with the limit switch 0-12 (N.C.) connected and
DIP2=OFF will the light switch off when the automation is open.
Automation open lamp. With DIP2=ON, the light switches off when the automation
is closed.
Lights kit (QIKLUX). The light switches off when the automation is open. If DIP2=OFF
connect to the terminals 1-12; if DIP2=ON connect to the terminals 1-11.
Motor 1 (M1). Terminal W must be connected to the common motor phase connection.
230 V~ / 5 A
The condenser must be connected between the U and V phases.
120 V~ [E1J]
Flashing light (LAMP). Activated during opening and closing operations.
120 V~ [E1J]
Courtesy light. Comes on for 180 seconds after receiving any opening (total or partial)
120 V~ [E1J]
or closing command.
Setting the operating time. From 10 to 120 s.
Note: with NC limit switch, set TM=MAX.
Setting automatic closing time. From 0 to 120 s.
With TC=MAX, the automatic closing is disactivated.
The count begins from the blocking of the automation, for the time set by the TC.
With DIP3=OFF, once a safety switch has been activated, the counter starts as soon as the safety
switch is released (for example, after passing through the photocells), and lasts for a period of time set
with TC (50%). Note: with DIP3=OFF and 6→4=OFF, the automatic closing is immediate.
With DIP3=ON, the counter starts when automation is opened and lasts for the entire duration set with
TC (100%).
Note: after the activation of the stop command, once contact 1-9 has closed again, the automatic
closing is only activated after a total or step-by-step opening command.
Power setting. Sets voltage supplied to motor.
Setting obstacle thrust. The control panel is equipped with a safety system that stops motion if an
obstacle is encountered during an opening operation and either stops or reverses motion during a
closing operation.
R1=MIN gives maximum obstacle sensitivity (minimum thrust).
R1=MAX disables detection (maximum thrust).
Description
Description
12

Publicidad

loading

Este manual también es adecuado para:

E1j