2 Technical data

Compressor
Pipe connection
Max. Flow rate
Max water pressure
Water temperature
Protection
Protection class
Micro-filter
Oil retention rate
Particle –backing rate
New filter element in
Deshydrator

2.1 Delivery

- ROPULS cleaning compressor including GK joint 1"
- Accessories: connection consisting of a reinforced hose and 1" joint
- Operating manual
- Test report.
- Optional accessories: ROCLEAN Injektor
Control panel with
Program keys
Coupling for
connecting hoses
Quick coupling for
Compressed air
connection
Pressure Indicator
Compressed air tank
Compressed air tank
Drain valve

2.2 Connecting to the power grid

Connect only to single-phase alternating current, and only on the rating plate on the voltage
specified. Connect only to properly grounded outlets. The machine may be operated only by a FI
circuit breaker with a rated fault current 30 mA max.
Connection: Insert the device into an electrical socket and press the green "RESET" button.
Once the red operation display has lit up, the device is ready to operate. Whenever the device is
removed from the socket or the power goes out, the device automatically shuts off.
Operational test: Press the blue "TEST" button: The device shuts off. Press the "RESET" button:
Once the red operation display has lit up, the device is ready to operate.
Always perform the operational test before starting up the device. If there is a repeated failure,
have the connected device inspected.
Please keep in mind that this device cannot replace fundamental safety precautions. To prevent
life-threatening hazards, be sure to use electrical devices only as intended.
Reliable personal protection against electric shock. Fault currents are recognized in a fraction of
a second, and the current supply is immediately interrupted. The risk to humans and animals is
drastically reduced.
- Never use the electric tool without a PRCD.
- The plug or electrical cord should be replaced only by the manufacturer of the electric tool
16
R 1" GK-coupling
5 m³ / h
max. 7 bar
30° C
IP 22
I
99,9 %
0,3 μm
Every 6 months
Suction, air, filter element and compressor
cleaning every month.
ENGLISH
Suction
200 l/min.
Working pressure
max. 8 bar
Tank capacity
9,5 litre
Motor output
1,5 kW
Main supply
~230 V, 50 Hz
Intermittent
S3 15%
LED display for flow rate and
dosage impulse
Suction- air filter compressor
Compressor
Connection for
Dosage pump
Switch
Rinse, Roclean injector
Frame on wheels
Pressure gauge for pressure
pulses of air
Air filter, Water separator