3. Drill the suspension holes in the ceil-
ing and use suitable dowels for the wall
material.
4. Align the mounting frame (1 and A)
screw it tightly onto the ceiling.
Now screw in the bolts for mounting the
hood (2 and C) until they protrude
~15mm from the ceiling.
5. Before using a lift to hang the extrac-
tor hood, you must remove the metal
filters.
To do this, use both hands to pull down
the metal filters until the magnet contact
24
Then release the locking hook on the
metal filters.
6. Then raise the extractor hood using
the lifting device (make sure it is facing
the correct way) to a distance of approx.
30 cm from the ceiling. At this point,
connect the hood to the power supply.
Pay attention to the area on the ceiling
in which the electrical supply line can be
routed!
7. Now unscrew the securing bolts (E)
on the hood upper section (B) while
holding the hood lower section (D) with
one hand.