Gewiss JOINON Serie Manual De Instalacion Y Uso página 51

Ocultar thumbs Ver también para JOINON Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 113
Preparation for device installation
The installation surface must be suitably prepared according to the type of ground, to guarantee that the device is stable during use. You
are therefore advised to use the base supplied (column version), fixing it to the ground by means of tie-rods (not supplied) or plugs, or
embedded in cement.
Install the charging station in the prepared area, maintaining the necessary distance between it and the surrounding area (as shown in
the figure).
The charging column can be installed in back-to-back configuration with another column, to make the best use of the space available.
This particular configuration requires only one power supply line and a single plinth for the installation of two devices, as shown below:
The two charging units must guarantee a minimum distance of 2 cm between the back-mounting boxes.
NB: the surface on which the charging station is to be installed must be designed and built in accordance with the standards and the
regulations in force, to ensure the safety of users regardless of the type of surface.
7.55.4.502.0 - Installation and Operation Manual
BACK
5 cm
50 cm
30 cm
FRONT
FRONT
2 cm
FRONT
50 cm
Gewiss
IT
EN
FR
ES
DE
RO
HU
NL
51

Publicidad

Tabla de contenido
loading

Tabla de contenido