Location of Your Dryer
Do Not Install Your Dryer:
• In an area exposed to dripping water or outside weather conditions.
• In an area where it will come in contact with curtains, drapes, or anything that
will obstruct the flow of combustion and ventilation air.
• On carpet. Floor must be solid with a maximum slope of 1inch (2.54 cm).
Installation in Recess or Closet:
• A dryer installed in a bedroom, bathroom, recess or closet must be
exhausted outdoors.
• Your dryer needs space around it for proper ventilation.
• A minimum of 120 square inches (774.2 square cm) of opening,
equally divided at the top and bottom of the door, is required. Air
openings are required to be unobstructed when a door is installed.
A louvered door with equivalent air openings for the full length of the door
is acceptable.
24 3/8"
(61.9 cm.)
9
ROUGH-IN DIMENSIONS
33 1/2"
(86 cm )
36 3/4"
(93.3 cm.)
DOOR OPEN 90˚
23 7/16"
(59.4 cm)