Sage the Oracle Touch BES990 Guía Rápida De Inicio página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 98
Troubleshooting
PROBLEM
Grinder Motor starts
but no ground
coffee coming
from grind outlet
Grinder Motor starts
but operates with a
loud 'clicking' noise
Unable to lock bean
hopper into position
Portafilter overfills
Grinder
Emergency stop?
Grinder running
continuously
POSSIBLE CAUSE
• No coffee beans in
bean hopper.
• Grinder/bean hopper
is blocked.
• Coffee bean may have
become stuck in hopper.
• Grinder is blocked
with foreign item or
chute is blocked.
• Moisture clogging grinder.
• Coffee beans
obstructing bean
hopper locking device.
• Tamping fan was
removed for cleaning
and not replaced.
• No beans in hopper.
• Tamping fan has
been removed.
WHAT TO DO
• Fill bean hopper with fresh coffee beans.
• Remove bean hopper. Inspect bean hopper
& grinding burrs for blockage. Replace
parts and try again.
• Remove bean hopper, inspect burrs
and remove any foreign body.
• Clean the burrs and grind outlet,
see page 12.
• Leave burrs to dry thoroughly before
re-assembling. It is possible to use a hair
dryer to blow air into the burr area to
quicken the drying process.
• Remove bean hopper.
Clear coffee beans from top of burrs.
Re-lock bean hopper into position.
• Check that the tamping fan is in position
and mounted correctly to the drive shaft,
see Instruction Book on Sage website.
• Rotate the portafilter to the left to stop
the auto grind, dose & tamp function.
• Unplug power cord from power outlet.
• Fill hopper with beans.
• Rotate the portafilter to the left to stop
the auto grind, dose & tamp function.
• Check that the tamping fan is in position
and mounted correctly to the drive shaft,
see Instruction Book on Sage website.
EN
15

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

The oracle touch ses990Oracle touch ses990