REQUIRED
INJECTOR
PRESSURE
9
1
Burner Tube Attaching Screws
2
Burner Support Bracket
3
Pressure Tap
4
Gas Valve
5
Gas Valve Flange
How to Adjust Gas Valve Governor/Regulator
1. Check gas injector (manifold) pressure as
follows. Refer to Figure 5.
2. Remove screw plug from inside pressure tap.
3. Connect a "U"-tube manometer (or similar
pressure gauge) to the injector (manifold)
pressure tap.
4. Start tumbler and note pressure once flame is
burning. Remove regulator cap and adjust
regulator screw until the injector pressure per
applicable table is achieved. Replace regulator
cap.
M414038
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
2
7
6
6
Spud Holder Nut
7
Spud Holder
8
Pressure Tap (Alternate location)
9
Manometer
Figure 5
1
1
Size Stamped on Orifice
3
5
T025K
BURNER INJECTOR
(ORIFICE)
Figure 6
Installation
4
T137K
T025KE1D
25