6. Installation and Safety Devices
6.1.
Recommendations for the correct use of the device
BEFORE SWITCHING
FILL IT UP UNTIL YOU REACH THE LEVEL WHICH CAN BE SEEN ON THE APPROPRIATE WINDOW
FOR VACUUM PUMPS TYPE
Remember to lock the balance with the appropriate block (Fig. 4) before the move (on uneven
terrain, uneven floors, etc.).
6.2.
Installation
The device has to be transported and set-up in vertical position. If you tip up the device, the oil from
the vacuum pump and the compressor may exit.
6.3.
Preparation of the Station
Unlock the balance before using the station
Before starting the station make sure that the power voltage is the same as the one indicated on
the plate placed near the side power socket (Fig 5).
WARNING:
T
HE STATION MUST BE CONNECTED TO THE ELECTRIC SOCKET
INDIRECT CONTACTS
IT IS ADVISED TO COMPLY CAREFULLY WITH THE HERE ABOVE SECURITY NORMS
PROVIDED TO ENSURE THE PROTECTION OF THE PERSONNEL
/
LIQUID
FREON UNDER PRESSURE
6.4.
Performable Operations
La COUNTRY CLIMA performs the following phases: recovery, recycling, vacuum and charging of air conditioning
systems for cars and industrial vehicles, which contain freon R134A.
The producer declines every responsibility deriving from improper use of other Freon types.
6.5.
Safety Devices
Security valve, calibrated at 16 bar for the internal bottle
Thermal protection for the compressor against overcharge (inside the compressor)
Electronic alarm for filling over 80% of the capacity and the minimum gas amount, which is necessary to
perform the recharge (< 1Kg)
Alarm of wrong operation in case of attempt to perform the vacuum with the system under pressure
Control display of the level of oil in the pump
Electronic pressure sensor for recovery compressor switching off and automatic control of the leaks
Electro valve for complete automatism of the functions
Display LCD board with electronic protection
Protection fuse on the switching-on module
Automatic bottle heating
14/04/2016
-
ON THE DEVICE PLEASE CHECK IF THERE
AV68 (ART. AV68I)
,
ACCORDING TO THE RULES IN FORCE IN THE COUNTRY OF USE
Vers. 2
IS OIL
IN THE VACUUM PUMP
.
ONLY
,
PROTECTED AGAINST
, WHICH USE
THE SYSTEMS AND THE COOLING
.
IF OIL IS MISSING
.
USE MINERAL OIL
Fig. 4 – Weigth
scale block
Fig. 5 – Voltage
Plate
.
THEY ARE
31