Motor Housing Pressure Test:
If oil has been drained, fill to normal level before per-
forming pressure test (See Figure 3). Remove pipe plug
from motor housing.
Apply pipe sealant to pressure gauge assembly and
tighten into hole. Pressurize motor housing to 10 P.S.I.
Use soap solution around the sealed areas above the oil
level and inspect joints for "air bubbles". For sealed areas
below oil level, leeks will seep oil. If, after five minutes,
the pressure is still holding constant, and no "bubbles" /
oil seepage is observed, slowly bleed the pressure and
remove the gauge assembly. Replace oil. Leak must be
located and repaired if pressure does not hold.
Seal Chamber Pressure Test
Set pump on its side with fill plug downward, remove plug
and drain all oil from seal chamber. Apply pipe sealant to
pressure gauge assembly and tighten
into hole in seal housing. Pressurize seal chamber to 10
P.S.I. and check for leaks.
Solids Handling Pumps
Models: ANC200, ANC300, ANC500,
ANC750, ANC1000, ANC1500 & ANC2000
Installation and Service
Oil Replacement Motor Housing
Remove pipe plug from motor housing.
Drain all oil (if not already done so) from motor housing
and dispose of properly per Local Code. Set pump upright
and refill with new cooling oil, see "Cooling Oil" chart. Fill
to just above motor as an air space must remain in the top
of the motor housing to compensate for oil expansion.
Apply pipe thread compound to threads of pipe plug then
assemble to motor housing. Check that o-ring is in place
and does not need to be replaced. Reassemble cord cap
to motor housing.
Oil Replacement Seal Chamber
Drain all oil (if not already done so) from seal chamber and
dispose of properly per Local Code. Place pump on its side
with plug upward, and refill with new oil (.75L), see "Cool-
ing Oil" chart. Apply pipe thread compond to threads of
pipe plug and assemble to intermediate coupling.
BP
Conoco
Mobile
Shell Canada
Texaco
10
DO NOT overfill oil. Overfilling of housing
with oil can create excessive and dangerous
hydraulic pressure which can destroy the
pump and create a hazard. Overfilling
oil voids warranty.
Cooling Oil
Recommended Supplier/Grade
Enerpar SE100
Pale Paraffin 22
D.T.E. Oil Light
Transformer-10
Diala-Oil-AX