USED FOR THE WATER SUPPLY MUST BE
OF ADEQUATE SECTION AND STRUC-
TURE (IF THE PRESSURE OF THE WATER
MAINS IS HIGH, WE RECOMMEND USING
A PRESSURE REDUCER AND A METAL
MESH PIPE).
►3.6.1. Connect the cooler to the water
mains by using the threaded fitting and the
solenoid valve.
►3.6.2. Connect the solenoid valve to the
electrical panel, by feeding the electrical
cables through the hole near the electrical
panel on the bottom of the cooler (Pic. 4).
►3.6.3. Make sure that there are no water
leaks in the circuit before commissioning.
►►►4. OPERATION
WARNING: Carefully read the "SAFETY
INFORMATION" before switching on the
cooler.
WARNING: Only use clean water to pre-
vent failures or other anomalies.
WARNING: Verify if your electronic sys-
tem is earthed correctly. Connection to
the mains must be made in compliance
with the National Standards in force.
Only power the cooler with the voltage
and frequency as specified on the name-
plate.
►►4.1. SWITCH-ON
►4.1.1. Connect the hose of the water supply
to the cooler's fitting (Pic. 7).
►4.1.2. Refilling the water tank. When the
tank reaches the maximum level, a float au-
tomatically stops the flow of water.
►4.1.3. Check that there are no leaks during
refuelling.
►4.1.4. Supply electricity to the cooler.
►4.1.5. Press ON/OFF / POWER to turn on
the cooler (Pic. 9).
►►4.2.1. FUNCTIONS OF THE CONTROL
PANEL AND REMOTE CONTROL (Pic. 8)
►ON/OFF: Is used to turn the cooler on or off.
►AUTO: Activates the automatic cooling cy-
cle. During operation, the appliance will al-
ternate the cooling cycle with the cleaning
cycle. The cleaning cycle time must be set
via the "SET" function and the "P1" sub-
menu.
►COOL: Activates or disables the cooling
mode (ventilation does not start immedi-
ately).
►VENT: Activates or disables the ventilation
mode.
►CLEAN: Activates the cleaning mode, which
will take a few minutes.
►REVERSE: Reverses the direction of rota-
tion of the fan, to introduce or remove air
from the room.
►SWING: Mode not available.
►▲ \ ▼: Adjusts the ventilation speed and
the control panel clock.
►CLOCK: It is used to set the control panel
clock.
►TIMING: Enables to activate or deactivate
the delayed switch-on or switch-off mode.
-Delayed
switch-on:
switched on, press the "TIMING" button to
set the delayed start (act on the ▲ \ ▼ but-
tons).
-Delayed
switch-off:
switched on, press the "TIMING" button to
set the delayed stop (act on the ▲ \ ▼ but-
tons).
NOTE: To reset the settings of the "TIMING"
mode, disconnect the power supply to the
cooler.
►SET: Sets some specific settings (press the
"SET" button several times and use the ▲ \
▼ buttons):
-P1: Setting the time between one cleaning
cycle and the next, when the cooler is set
to the "AUTO" function (you can choose to
set the cleaning cycle from 3 to 72 hours,
however, we always recommend setting the
value to the lowest number of hours in order
to prevent any risk).
-P2: Room temperature setting from 10°C
to 40°C (with probe disconnected see Pic.
5).
-P3: Room relative humidity setting from
20% Rh to 40% Rh (with probe connected
see Pic. 5).
-P4: Electric frequency setting from 40Hz to
60Hz.