Descargar Imprimir esta página

Starting - Stopping - Mosa GE 4500 HBS Manual De Instrucciones

Publicidad

STARTING - STOPPING

check daily
NOTE
!
Do not alter the primary conditions of regulation
and do not touch the sealed parts.
STARTING
1. Turn the fuel cock (87) to ON.
2. Switch the choke control (66) to CLOSE
N.B.: Do not use the air valve if the motor is hot or the
air temperature is too high.
CLOSE
3. Turn the engine switch (28) to the ON position
ENGINE SWITCH
FUEL COCK
CHOKE LEVER
CLOSE
GE 3200 SX
GE 4500 HBS
GE 4500 HBS-AVR
4. Lightly pull the start-up knob (73) until meeting resi-
stance, then pull decisively.
+ ATTENTION:
Allow the start-up knob to re-enter slowly, avoiding having
it knock against the motor and thereby damaging the
start-up system.
MANOPOLA DI AVVIAMENTO
5. Once the engine is started, with the starter off, let it
turn for a few minutes before drawing the load.
ENGINE STOPPING
For shut down the motor in case of emergency, turn the
motor switch (28) to OFF.
To stop the motor under normal conditions, proceed as
follows:
- interrupt the power source, switching off all tools
connected. If a tool does not feature a power
switch, lower the G.F.I. switch lever (D);
- allow the motor to run without any load for a
few minutes;
ENGINE SWITCH
-
Turn the engine switch (28) to OFF.
-
Turn the fuel valve to the OFF position.
CAUTION
!
RUNNING-IN
During the first 50 hours of operation, do not use more
than 60% of the maximum output power of the unit and
check the oil level frequently, in any case please stick
to the rules given in the engine use manual.
M
26
REV.0-01/08
FUEL VALVE

Publicidad

loading

Este manual también es adecuado para:

Ge 4500 hbs-avr