The SB02P control unit with microcontroller can be used with motors with power not exceeding 500W.
N.B.: If two motors are used on an overhead door, the two 9
µ
by a 16
F capacitor.
Adjustment of the motor torque
The motor torque can be adjusted by turning the special trimmer.
Pickup function
It allows the maximum motor torque for about 1 sec. when the motor is started.
The pickup can be disabled by moving the Dip-Switch "DSW8"= Off.
Installation instructions.
a) The electrical installation and functioning logic must comply with current standards.
b) Keep the power cables (for the motor and power supply) away from the control cables (buttons, photo-
cells, radio). To avoid interference use two separate sheaths (see EN 60204-1 15.1.3).
c) Check all the connections again before supplying voltage.
d) Check that the Dip-Switch settings are as required.
e) When the unit is powered the LED "PGM" should flash, conversely check the correct operation of the
fuses and that 230Vac, 50Hz be present along terminals 1 and 2 (INPUT 220VAC - keep to phase/neutral).
f) If the "STOP push-button" is not in use, this should be short-circuited with the "BYPASS" dip-switch
number 1.
g) If the direction of the motor rotation is not correct, invert the "OPEN" - "CLOSE" wires of the motor and
the limit switches wires "FCA" - "FCC".
Input/Output functions
(1,2)
INPUT 220VAC= Control unit power supply 230Vac, 50Hz (keep to phase/neutral).
(3,4)
CORTESIA= Courtesy light (230Vac).
(5,6)
LAMP220= Flashing light at 230Vac.
(7,8)
Scale= Free contact for timed relay, lighting of stairs.
(9,10)
ELS= Power supply output, Electric lock 12Vac.
(11,12,13) CHIUDE/APRE/COM= To the relevant motor terminals at 230Vac, 50Hz.
It is mandatory to connect the Earth wire (yellow/green) on the motor frame).
(14,15)
24VAC= Power supply, Auxiliary.
(16)
+V= Common to all control inputs.
(17)
CHIUDE= Input, push-button CLOSE (N.O. contact).
(18)
APRE= Input, push-button OPEN (N.O. contact).
(19)
P.P.= Input, Step-by-step button (N.O. contact).
(20)
STOP= Input, STP button (N.C. contact).
(21)
FTC= Input, photocell receiver (N.C. contact).
(22)
FCA= Input, Open limit switch (N.C. contact).
(23)
FCC= Input, Close limit switch (N.C. contact).
(24,25)
DAS= Input, Safety Edge*.
(26,27)
RX 2CH.= Radio module 2
(28,29)
ANT.= Input, radio module contact.
* The input of the safety edge is a calibrated input resistance.
If a resistive safety edge is used, close the Jumper J1 located near the input of the safety edge.
If a mechanical safety edge is used, open the Jumper J1 located near the input of the safety edge.
If no safety edge is provided, open the Jumper and short circuit the input through the special DSW (Number
5, see table hereunder).
Dip-switch functions "SELECT"
DSW1= Operating mode for "P.P." (Step-by-Step) button and remote control.
Off= Operation: "APRE" - "STOP" - "CHIUDE" (OPEN - STOP - CLOSE)
On= Operation: "APRE" - "CHIUDE" - "APRE" (OPEN - CLOSE - OPEN)
DSW2= It enables or disables the automatic closure "Trimmer TCA".
Off= Automatic closure disabled
On= Automatic closure enabled
DSW3= It enables or disables the "multi-flat" function (after the first opening control, the "P.P. push button"
and the Remote control are disabled).
Off= Multi-flat function disabled
On= Multi-flat function enabled
DSW4= It enables or disables the forewarning light.
Off= Forewarning light disabled
SB02P Control unit with microcontroller
nd
channel contact (N.O. contact).
µ
F capacitors must be removed and replaced
7