5 . Trouble shooting
POSSIBLE CAUSE
The plug of the appliance is not
connected to the socket.
The plug has become loose.
The socket is not supplied with
energy.
The fuse is switched off.
The voltage is too low.
Incorrect energy supply.
The appliance has been switched off
for a while.
Doors opened too often or too long.
The door was frequently opened.
The door is not properly closed.
Encrusted ice inside the appliance.
The current temperature setting is
too warm
Warm or hot beverages inside the
appliance.
The appliance is overfilled.
The door seals are damaged.
The door is not properly closed.
The door seal is damaged or soiled.
The door seals are soiled.
The appliance is not installed on a
level, dry and solid floor.
The appliance is in contact with a
wall or another item. The bottles are
incorrectly positioned.
Some items have dropped behind
MALFUNCTION
The appliance does not work at all.
The compressor does not work at all.
The compressor operates for too long.
Unsatisfactory cooling capacity.
Strong formation of encrusted ice.
The door makes a strange sound when opened.
Unusual noise.
the appliance.
MEASURE
Check the corresponding socket by
connecting it with another appliance.
Check the fuse box.
Compare the data on the model
plate with the data of your energy
supplier.
Check the energy supply.
The appliance needs some time to
reach the preset temperature.
Do not open the door too often/too
long.
Select a different setting if necessary.
Check the door/door seals.
Defrost the appliance.
Close the door.
Clean/replace the door seal.
Clean the seals.
Realign the appliance.
Readjust the appliance.
Realign the bottles
Remove these items.
11