1.5
MAIN COMPONENTS
Codice/Code 8111221
Modello/Model MURELLE EQUIPE 100 BOX (M)
Matricola/Serial n. 9999999999
PAR 1 = 6 (G20) / 14 (G31)
PAR 2 = 9
KEY
1 System return manifold
2 Gas tap
3 System supply manifold
4 Gas valve
5 Fan
6 Safety thermostat 95°C
7 Heating supply probe (SM)
8 Ignition electrode
9 Control panel
10 Detection electrode
11 Pressure transducer
12 Single module drain
13 Safety valve 3.5 bar
14 Pump with air release vent
15 System supply tap
16 3-way drain tap
17 Gas manifold
CAUTION: To access the control panel (9) remove
the two screws which secure it to the support
bracket and turn the panel downwards.
38
9
8
7
6
5
4
3
2
1
10
11
12
13
14
15
16
17
Fig. 3