This constant indicates motor movement per 1000 rpm – expressed numerically to calculate speed and distance (DO NOT TOUCH).
0 – MODE A – Automatic door operation with lock release
1 – MODE B - automatic door operation with user-set opening width
2 – ENERGY SAVING MODE – automatic door operation with two different opening distances activated automatically according to type of transit
3 – TWO-STOP MODE – automatic door operation with total or partial opening as set by user
4 – 2-POSITION PUSHBUTTON MODE – automatic door operation with separate open and close pushbuttons
5 – SINGLE CONTROL MODE – automatic door operation with single pulse or radio control
6 – CONTROL MODE – dead-man control in opening only; automatic closing with safety devices enabled
7 – THREE-STOP MODE – automatic door operation with 3 different opening modes from 3 different controls.
perture diverse date da 3 comandi diversi
USE: "automatic door operation" with normal opening/closing manoeuvres.
Operation is within the distances set by means of function CO-02.
When the SYS control is activated, the door opens to the mechanical limit switch.
When the SYS signal switches off the door closes and returns to normal automatic door status (the SYS control opens the door and keeps it open until
the control is released). If the D/N switch (Day/Night function) is set to DAY (closed contact), the electric lock is permanently released and enables
opening both on the internal and external sensor and also on photocells.
If set to NIGHT (open contact) it enables the electric lock on operation and inhibits operation of the external sensor.
Wait time before automatic closing is set by means of CO-09.
Closed door pressure is set by means of function CO-10.
Circuit board connections:
Connect output sensors (INSIDE) and input sensors (OUTSIDE) to the relative terminals.
Set 1 or 2 pairs on the photocell circuit and then connect the RIB photocells to wires 4-5 (0-LIMIT). Connect other types of sensors and pushbuttons
to HELP to enable opening. A switch for the SYS control should be fitted (the SYS control opens the door and keeps it open until the control is
released).
An emergency pushbutton can be fitted by connecting it to the STOP terminals. A switch/selector should also be fitted to the DAY/NIGHT input to
enable selection of the day/night mode.
Lock connection: fit the connector on terminal CN5 on the control unit.
Programmer parameter setting procedure
Turn on the power supply
Press STOP on the programmer
Press DATA-ENTER - "CO-00" appears on display
Press the up key once - "CO-01" is displayed
Press DATA-ENTER on CO-01 to enter the Options menu
Select option "0" by means of the up/down keys.
Press DATA-ENTER to confirm the selection – "CO-02" appears on display.
Press DATA-ENTER on CO-02.
Set the opening width by means of the up/down keys (to select the specific display use key >, the selected item flashes).
Press DATA-ENTER to confirm the selected width – CO-03 appears on display.
Press the up key until CO-39 is displayed
Press DATA-ENTER on CO-39.
Enter the door weight by means of the up/down keys (to select the specific display use key >, the selected item flashes).
Press RUN on the programmer.
Turn the main door switch off and on again and perform an operation check.
Circuit board wiring diagram for normal operating mode
CO-00
SPEED CONSTANT
CO-01

OPERATING MODE

- 0 - MODE A -