Circuit board connections:
Connect the open control to wires 5-7 (0-HELP) and closing to wires 5-6 (0-SYS) by means of pushbuttons, selectors or sensors. Set one or 2 photocell
pairs and connect to wires 4-5 (0-LIMIT). An emergency pushbutton can be fitted by connecting it to wires 8-9 (0-STOP). A switch/selector should also
be connected to wires 3-5 (-0V-D/N) to enable selection of the day/night mode.
N.B. INSIDE AND OUTSIDE INPUTS IN THIS CONFIGURATION ARE NOT ENABLED (however, sensors can be connected to the HELP and SYS
inputs to control automatic door closing/opening )
Programmer parameter setting procedure
Turn on the power supply
Press STOP on the programmer
Press DATA-ENTER - "CO-00" appears on display
Press the up key once - "CO-01" is displayed
Press DATA-ENTER on CO-01 to enter the Options menu
Select option "4" by means of the up/down keys.
Press DATA-ENTER to confirm the selection – "CO-02" appears on display.
Press DATA-ENTER on CO-02.
Set the opening width (max. opening) by means of the up/down keys (to select the specific display use key >, the selected item flashes).
Press DATA-ENTER to confirm the selected width – CO-03 appears on display.
Press the up key until CO-39 is displayed
Press DATA-ENTER on CO-39.
Enter the door weight by means of the up/down keys (to select the specific display use key >, the selected item flashes).
Press DATA-ENTER to confirm the selected value – CO-40 appears on display.
Press RUN on the programmer.
Turn the main door switch off and on again and perform an operation check.
Circuit board wiring diagram with 2-PUSHBUTTON operating mode.
- 5 - SINGLE CONTROL MODE -
USE: Opening and closing functions are controlled by a single pulse (HELP). When open, the door does not close until it receives a closing signal via
the same pushbutton. During closing the door can be re-opened by a signal from LIMIT (photocell); after opening it closes immediately.
If the D/N switch (DAY/NIGHT function) is set to DAY (closed contact), the electric lock is permanently released and opening via photocells is also
enabled. After opening, the door closes automatically.
If set to NIGHT (open contact) the electric lock is enabled and the photocells are enabled during closing only.
Circuit board connections: Connect the open and close pushbuttons to wires 5-7 (0-HELP). Set 1 or 2 pairs on the photocell circuit and connect to
wires 4-5 (0-LIMIT). An emergency pushbutton can be fitted by connecting it to wires 8-9 (0-STOP). A switch/selector should also be connected to wires
3-5 (-0V-D/N) to enable selection of the day/night mode.
N.B. INSIDE AND OUTSIDE INPUTS IN THIS CONFIGURATION ARE NOT ENABLED
Programmer parameter setting procedure
Turn on the power supply
Press STOP on the programmer
Press DATA-ENTER - "CO-00" appears on display
Press the up key once - "CO-01" is displayed
Press DATA-ENTER on CO-01 to enter the Options menu
Select option "5" by means of the up/down keys.
Press DATA-ENTER to confirm the selection – "CO-02" appears on display.
Press DATA-ENTER on CO-02.
Set the opening width (max. opening) by means of the up/down keys (to select the specific display use key >, the selected item flashes).
Press DATA-ENTER to confirm the selected width – CO-03 appears on display.
Press the up key until CO-39 is displayed
Press DATA-ENTER on CO-39.
Enter the door weight by means of the up/down keys (to select the specific display use key >, the selected item flashes).