5.5.2.5 - Safety rules

Never dowse the fire with water to put it out.
The front glass as well as other parts of the stove
are very hot : be aware of the risk of burns,
particularly when small children are present.
The fireplace radiates a significant amount of
heat even through the glass : do not place heat-
sensitive materials or objects at a distance closer
than 1.50m from the glass.
Empty the ash pan into a metal or nonflammable
container intended for this purpose. Although the
ashes may appear to be cold, they may still be
very hot even after a long cooling-down period.
Do not place easily inflammable materials near
the fireplace or in the woodbox.
Cautious, do not store the firewood under the
appliance (Fig. 19).
In case of fire in the hearth, turn the thermostat
on position 0 and close the ventilation duct.
6
-
MAINTENANCE
INSTRUCTIONS
6.1 - Maintenance and sweeping of the chimney
flue
The chimney flue must be mechanically swept.
This operation should be performed several times
per year and at least once during the heating
season. A certificate should be handed in by a
qualified professional.
Prior to sweeping operations :
Set down the deflector, the fireback, and the
-
joining up pipe.
Proceed with the dismantling of the deflector :
-
Have the deflector got through P guide
pins (Fig. 22) and have it out off
slantwise (Fig. 23).
Dismantling of the ventilation shaft :
after having dismantled the deflector
(Fig.20, 21 and 22 ) loosen the ( A )
screw ( box spanner H 10 ), partially
free the lever and its operating lever
stem, without getting them out off the
grate, in order to free the shutter (Fig.
24).
NOTA BENE : Have the lever on
vertical position to have the spin
getting through the grate easily.
Reassembly of the ventilation shaft :
for the reassembly act the other way
round
(vertical
vertical shutter) and that the shutter
horizontally positioned (circular rib
must be in contact with the horizontal
part inside the appliance) to ensure
the water tightness.
AND
SWEEPING
box
spanner
for
NOTA BENE : For the deflector, the
E notches are located at the fore
part of the appliance (Fig 25) when
this last one is set up.
For reinstall the deflector, carry out the same
-
operations in the reverse order.
Thoroughly inspect the condition of the
-
fireplace and all seals, in particular : seals,
locking mechanisms, bearing surfaces (door,
frame).
After removing the tube cover :
-
Thoroughly inspect the condition of the
.
chimney flue and the connecting tube: all
connections must be mechanically sound
and retain their tightness.
Use a vacuum cleaner to clean the
.
convection circuit around the fireplace,
inside the hood and in the hot air outlets.
Clean the appliance using a brush and a vacuum
cleaner.
If an anomaly is detected, have the unit or the
installation repaired by a certified professional.
After a long off-period :
Check that nothing obstructs any pipes before using
the stove again.

6.2 - Routine maintenance

Clean the glass with a damp cloth and remove
the ash. If necessary, use a special cleaning
product in accordance with the manufacturer's
instructions. Wait until the installation has
completely cooled down before performing this
operation.
Clean regularly the ventilation guides :
Using the tip of a metallic object (2), scratch
-
the inner edges of the cast iron to remove the
soot which may have formed.
Using a vacuum cleaner (1), remove the
-
particles and dust trapped between the door
and window (Fig. 26 and 27).
NOTE : The particles disrupt the formation of the
secondary air layer which protects the glass
from direct contact with the smoke and
assists in the complete combustion of the
wood.
These operations should be performed
whenever the glass is dirty and only once
the fireplace has completely cooled down.
Regularly clean the hot air outlets on the tube
cover. The outlets become quickly obstructed
with intensive operation. Select an adequate
cleaning interval.
20