Electrical Connection; Heating Lamps; Start-Up - Arneg Sydney 3 TCBM Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Sydney 3 TCBM-TCPW
English
the limits of 25°C; R.H. 60%.
N.B. All these operations should be performed by specialized technical personnel only.

8. Electrical connection

- The unit must be protected upstream by an automatic differential omnipolar thermomagnetic switch
with appropriate characteristics. This must also act as a general power disconnection switch.
- Inform operators of the switch location so that it can be reached quickly in the case of an
EMERGENCY.
- The electrical system must be earthed.
- First check that the voltage supply is as specified on the plate data.
- To guarantee correct operation, the maximum voltage variation must be between +/- 6% of the
nominal value.
- Check that the power line has appropriate section cables, is protected against overcurrent and
dispersions towards earth, in compliance with current standards.
- For power supply lines longer than 4-5 m, increase the cable cross section correspondingly.
- In the event of an interruption to the electricity supply, check that all other electrical appliances can
restart without causing the overload protections to intervene. If not, alter the system in order to
differentiate between the start-up of the various devices.
- The installer must supply the anchorage devices for all cables in and out of the unit.
The automatic differential thermomagnetic switch should be designed so as to not open the neutral
circuit without simultaneously opening the phases. In any case, the opening distance for the contacts
must be at least 3mm.
N.B. All these operations should be performed by specialized technical personnel only.

9. Heating lamps

To ensure the products on display are kept at a constant temperature, the unit is supplied with heating
lamps. The heating lamp switch is located on the control panel, par. 10 No. 5.
WARNING! Heating lamps and outer surfaces in direct light reach high temperatures.
Use personal protection equipment to protect the upper body from heat and from
accidental contact with hot surfaces.
Adopt all the necessary preventive measures to avoid contact with such surfaces by
untrained personnel.

10.Start-up

- Set the main switch to ON to check whether the control panel and the necessary components are in
working order.
- All controls are equipped with LEDs to indicate whether the component is working.
- The only non-lit switch is the top heating light switch.
The control panel is located in the operator area on the bottom of the cabinet and is made up of:
Hot Case Pie-Warmer Version (TCPW)
1 - Mains switch
2 - Line
3 - Tank thermostat
4 - Heating light
5 - Light heating
6 - Anti-condensation ventilation.
18
2
1
3
4
5
6
05060109 00 01/04/2010

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sydney 3 tcpw serie90 tcbm90 tcpw100 tcbm100 tcpw

Tabla de contenido