2.8.
Casi di utilizzo avanzato
Questo paragrafo illustra alcuni casi di utilizzo avanzato.
Di seguito: qualsiasi tasto del telecomando può comandare qualsiasi uscita del ricevitore
2.8.1 Procedura di impostazione avanzata
ADD/REMOVE operation for a chosen relay
1/ Select «Add/Remove» mode with SW5 ON.
2/ Select SW3 OFF and SW4 OFF.
3/ Select the relay that the remote control is to be used to control by setting switches SW1 and SW2 (cf Table
below). Note: consider switching the switches to ON again if bistable mode is required.
4/ Press any key on the remote control.
5/ Exit «Add/Remove» mode with SW5 OFF.
Two results are possible with this operation:
This association had not been set up previously. The association is now created. The LED flashes once.
This association had been set up previously. The association is erased. The LED flashes twice.
ERASE operation for a relay
1/ Select «Erase» mode with SW4 ON.
2/ Select SW3 OFF and SW5 OFF.
3/ Select the relay for which the associations need to be erased by setting SW1 and SW2.
4/ Press any key on the remote control.
5/ Exit «Erase» mode with SW4 OFF.
Result of the operation:
The output chosen can no longer be activated by any remote-control. The LED flashes twice.
Di seguito: selezione di relè in modalità di impostazione avanzata
Gamme ARF18 UG V1.6
ARF18 receiver
+V
ARF18 receiver
Output 1
+V
Output 1
Output 2
0V
Output 2
Output 3
0V
Output 3
Output 4
Output 4
Remote control 1 drives
output 1 with key 1
output 3 with key 4
Remote control 2 drives
output 1 with key 2
output 2 with key 3
Remote control 3 drives
outputs 1 and 4 with key 3
106