2.

Relay receivers

2.1.

Product installation

The ARF7341 is fixed via the attachment lugs on the top (aerial) and bottom (sealed housing) of the casing. Any
work carried out (drilling...) on the casing will cause it to lose its IP65 watertight approval.
Remove the two stainless steel screws (A and B) and release the lower part to access the power supply termi-
nals and the contacts.
2.2.

Power supply voltage

The product must be powered with a 15 to 30V DC power supply that complies with SELV (note: maximum vol-
tages that should not be exceeded: 42.4Vac or 60Vdc).
The product's power supply must comply with EN 60950-1 (2006 ed) or EN61010-1 and must be of limited power
(§ 2.5 of EN 60950-1 (2006 ed)).
The power supply and relay cables must be 6.5 mm in diameter (1 & 2 relays) or 10 mm (4 relays), black in
colour, and be able to carry a current of 10 amperes/per conductor. The number of conductors (cf ¶ 2.2) must
correspond to the number of relay terminals used, plus those required for the power supply.
Each multi-strand connector must be equipped with an end.
Switch off the power supply, then connect the power supply to the screw terminals marked + and -.
Gamme ARF18 UG V1.6